24
Dräger Polytron 5200 / Dräger Polytron 53X0
Technical data
8
Technical data
8.1
Approvals
See printout of approval label.
8.2
Marking
The marking is reproduced on a separate piece of paper
shipped with the transmitter.
Serial No. key: The year of manufacture is indicated by the
third letter in the serial number: A = 2009, B = 2010, C = 2011,
D = 2012, E = 2013, F = 2014, H = 2015, J = 2016, K = 2017,
etc.
Example: Serial No. ARBH-0054: the third letter is B, which
means that the unit was manufactured in 2010.
8.3
Signal transmission to central
control unit
8.4
Voltage of power supply
8.5
Tightening torque
8.6
Tightening torque and wire size for field
wiring terminals
In case of optional increased safety terminal box, securely
screw the transmitter onto the e-box using 4 screws with a
tightening torque of 8 Nm.
Current
Meaning
4 mA
Zero point
20 mA
Full scale deflection
< 1.2 mA
Fault
3.8 mA to 4 mA
Sensor drift below zero
20 mA to 20.5 mA
Measuring range exceeded
> 21 mA
Fault on the analog output
3.4 mA steady or 1 Hz
modulation between
3 and 5 mA (user
selectable)
Signal for maintenance mode
Sample
Operating Voltage
3-core shielded cable, 10 to 30 VDC
In-rush Current
300 mA for 140 msec @ 24 VDC
350 mA for 140 msec @ 24 VDC with
relay option
Operating Current
(maximum)
95 mA @ 24 VDC w/o relay non-
remote sensor
145 mA @ 24 VDC with relay remote
sensor
Relay Rating
SPDT 5 A @ 230 VAC, 5 A @ 30 VDC,
resistive load
Part
TQ Lb. In.
TQ Nm
lid
min. 266
min. 30
sensors
min. 266
min. 30
plugs
min. 266
min. 30
conduit hubs
min. 443
min. 50
instrument to e-box
71
8
Electronic
TQ Lb. In.
Wire Size AWG
Wire Size mm
2
All field wiring
terminals
4.4 - 7.0
(0.5 - 0.8 Nm)
24 - 12
0.2 - 2.5
www.norrscope.com