Line Voltage                                  220VAC/ 50 Hz or 110VAC / 60Hz 

Current Consumption                    Max.1.25 Amp (fan high, light on) 

                                                          Min.0.62 Amp (fan low, light off) 

Air Volume Output                        Fan speed Flow 

Low 120 CFM 

High 330 CFM 

Air Flow Characteristics          40cm×120cm Area Coverage 

Light Output                                  1650 Lumens Total. 

Replacement Lamp                13-15 Watt Energy Saving Fluorescent 

Operating Temperature                32º

F(0

)

122º

F(50

 

Enclosure                                          Aluminum 

Finish                                                Powder Coat 

Size                                                 

1100mm(L)×170mm(W)×125mm(H) 

Optional Air Filter                    30PPl Open Polyurethane Foam 

Ion Balance(offset voltage)    0V+/-10V(It requires no calibration) 

 

3. INSTALLATION   

The  SL-003  Ionizing  blower  should  be  located  600  to  900mm 

above  work  surface  with  center  fan  directly  above  critical  area.  There 

should  be  no  cross  flow  of  air  between  unit  and  work  surface.  Drafts 

from air conditioning or heating air outlets can affect the performance of 

this device. 

 

3.1    Mounting 

The  SL-003  unit  may  be  mounted  using  adjustable  mounting 

brackets.  The  mounting  brackets  are  designed  for  use  on  a  variety  of 

surfaces such as: perforated steel angle, uninstructed metal framing and 

on Metro wire shelving. Place a lock washer and flat washer on the lock 

Summary of Contents for SL-003

Page 1: ...1 INSTRUCTION SL 003 IONIZING AIR BLOWER DR SCHNEIDER PC...

Page 2: ...an overhead unit designed to provide total coverage for electrostatic problems Please read the instruction manual completely before installing or operating the device This device is equipped with a 3...

Page 3: ...olyurethane Foam Ion Balance offset voltage 0V 10V It requires no calibration 3 INSTALLATION The SL 003 Ionizing blower should be located 600 to 900mm above work surface with center fan directly above...

Page 4: ...performed by qualified personnel The color cord for wiring the plug is as follows Red line Blue Neutral Green Yellow Ground 4 OPERATION Activate the SL 003 Overhead Ionizing Air Blower by turning FAN...

Page 5: ...the point cleaners The SL 003 also contains a balancing circuit that is inherently self balancing This circuit compensates for emitter point wear line voltage fluctuations and variations in air veloci...

Page 6: ...ures are subject to the variation in the atmospheric conditions 4 Discharge times are in seconds from 1000 volts to 100 volts If a charged plate monitor is not available a hand held electrostatic fiel...

Page 7: ...not insert objects through intake or outlet grille Do not try to verify operation of unit by drawing a spark from an ion emitter point The design of the balancing circuit makes the park test inconclu...

Page 8: ...r flickers the compact fluorescent lamp should be replaced as soon as possible Access to lamp is provided by removing the front panel of the device Disconnect the device by unplugging line cord Remove...

Reviews: