background image

TAINY IQ Security Instructions 

 
 

 

User’s Manual 

The User’s Manual is available for you as download on our website: 

www.neuhaus.de 

or

 www.sagemcom.com 

Products 

The  name  TAINY IQ  is  used  hereinafter  as  a  collective  term  for 
TAINY IQ-LTE and TAINY IQ-LTE 6E. 

Safety 

General: 

The  product  TAINY  IQ  complies  with  the  European  standard  EN 
62368-1, 

Safety 

of 

Information 

Technology 

Equipment. 

Read the installation instructions carefully before using the device. 
Keep the device out of reach of children, especially small children. 
The  device may  not  be installed or  operated  outdoors  or  in  damp 
areas. Do not put the device into operation if connecting cables or 
the device itself is damaged. 

Operation: 

The device may only be used in the cases of operation which are 
described  in  the  datasheets  and  the  manual.  A  proper  and  safe 
operation of the device presumes an appropriate transport, storage, 
mounting  and  installation  as  well  as  a  careful  handling  and 
maintenance. 

Installation: 

The installation of the TAINY IQ may be carried out only by qualified 
electricians in accordance with the recognized rules of engineering 
and 

regulations 

which 

apply 

to 

the 

installation 

of 

telecommunications  equipment  and  devices.  In  operation,  the 
TAINY IQ needs to be covered by a bezel or housing that provides 
adequate  protection  against  accidental  contact  of  dangerous 
voltage. 

External Power Supply: 

The TAINY IQ may only be supplied via power supplies according 
to IEC/EN 62368-1 Annex Q "Limited Power Source". The external 
power supply for the TAINY IQ must comply with the requirements 
for NEC Class 2 circuits as defined in the National Electrical Code 
® (ANSI/NFPA 70). The output voltage of the external power supply 
must  not  exceed  60V

DC

.  The  output  of  the  external  power  supply 

must be short-circuit-proof. 
When connecting to a battery or rechargeable battery, ensure that 
an all-pole disconnecting device (battery main switch) with sufficient 
disconnecting  capacity  and  a  fuse  with  sufficient  disconnecting 
capacity  is  provided  between  the  device  and  the  battery  or 
rechargeable  battery.  Observe  the  section  Technical  Data  of  the 
user  manual  and  the  instructions  for  installation  and  use  of  the 
respective  manufacturers  of  the  power  supply,  the  battery  or  the 
rechargeable battery. 

In Port and Switching Output: 

The in port and switching output are both galvanic insulated against 
all  other  terminals  of  the  TAINY IQ.  If  the  external  installation 
connected  to  the  TAINY IQ  connects  a  signal  of  the  in  port  and 
switching  output  galvanically  to  a  power  supply  signal  of  the 
TAINY IQ,  the  voltage  between  each  signal  of  the  in  port  and 
switching  output  and  each  signal  of  the  power  supply  may  not 
exceed 60V

DC

Handling Cables: 

Never pull on the cable to pull a cable plug out of its socket; instead 
pull  on  the  plug. Always  use  edge  protectors  when  routing  cables 
over  sharp  corners  and  edges.  Provide  adequate  strain  relief  for 
cables when necessary. 
For safety reasons, ensure that the bending radii of the cables are 
observed. Failure to observe the bending radii of the antenna cable 
will degrade the device's transmitting and receiving characteristics. 
The bending radius must not be less than the minimum of 5 times 
the  cable  diameter  statically  and  15  times  the  cable  diameter 
dynamically.

 

Wireless Device: 

Never  use  the  device  in  areas  where  the  operation  of  wireless 
equipment is prohibited. The device contains a wireless transmitter 
that may degrade the function of electronic medical devices such as 
hearing aids or pacemakers. Please consult your physician or the 
manufacturer of such devices. To prevent demagnetization of data 

storage media, do not place any floppy disks, credit cards or other 
magnetic data storage media near the device.

 

 

Antenna Installation: 

Please use only antennas from the accessories for the TAINY IQ.  
These antennas are tested by us and ensure the product features 
described. When installing the antenna, make sure that a sufficiently 
good  signal  quality  is  present.  Use  the  signaling  lights  of  the 
TAINY IQ which show the signal quality. 
  
The antennas used must have the following characteristics: 
Passive, Gain < 1,5 dBi, VSWR < 2,0:1, Impedance 

50 Ω, matched 

for  GSM  (900  MHz,1800  MHz)  UMTS  (900  MHz,  2100  MHz,  LTE 
(800 MHz, 900 MHz, 1800 MHz, 2100 MHz, 2600 MHz). 
 

RF-Exposure: 

The conformity test concerning the compliance of basic limits for the 
safety  of  persons  in  electromagnetic  fields  (10  MHz  to  300  GHz) 
was  carried  out  using  calculations  in  accordance  to  EN  62479 
[2010] assuming a maximum average transmission power of 0.25W, 
an  omnidirectional  antenna  with  a  gain  <  1.5  dBi  and  a  minimum 
distance to persons of 20 cm. 
When  using  an  antenna  with  directivity,  the  compliance  with  the 
basic  limits must  be  rechecked, considering the changed  antenna 
characteristics. 

Warning about Costs! 

Please  note  that  data  packets,  which  are  subject  to  charges,  are 
even  exchanged  when  a  connection  is  (re-)  established  when  an 
attempt to connect a remote station is made (e.g. server is switched 
off,  wrong  destination  address,  etc.)  as  well  as  to  maintain  an 
established connection.  In  example,  a  remote  station  which  is  not 
available  may  cause  unwanted  significant  costs  because  of  a  big 
number of unsuccessful connection retries.

 

CE Conformity 

 

Simplified CE Declaration of Conformity

 

Sagemcom Dr. Neuhaus GmbH hereby declares that the radio systems type TAINY 
IQ-LTE and type TAINY IQ-LTE 6E comply with Directive 2014/53 / EU. The 
complete text of the EU declarations of conformity is available at the following 
Internet addresses: 
 

www.neuhaus.de oder www.sagemcom.com 

 

Frequency bands:

 GSM/GPRS/EDGE: 900/1800MHz / UMTS/HSPA+: 

900/1800/2100MHz / LTE: 800/900/1800/2100/2600MHz 
 

Max. tx power:

 Class 4 (2W) for EGSM900 / Class 1 (1W) for GSM1800 

Class E2 (0,5W) for GSM900 8-PSK / Class E2 (0,4W) for GSM1800 8-PSK 
Class 3 (0,25W) for UMTS/HSPA+ / Class 3 (0,20W) for LTE 

GPRS/EGPRS Multi-slot Class 12 

 

 
 
 

Copyright Statement 

The posting in this publication are protected by copyright. Translations, reprints, 
reproduction and storage in data processing systems require the express consent 
of the manufacturer. 

Subject to technical modifications. 

All trademarks and product names are trademarks, registered trademarks or 
tradenames of their respective owners. 
All information are based on manufacturer's specifications. No guarantee or liability 
for incorrect entries or omissions. 
The contents of this manual and the technical specifications are subject to change 
without notice. The descriptions of the specifications in this manual do not constitute 
a contract. 

Doc.-No. 3201AD001 rev. 1.1 / 11/2019 

 

Reviews: