![Dr. Escherich TAIFUN-CLEAN 014 Operating Instructions Manual Download Page 28](http://html1.mh-extra.com/html/dr-escherich/taifun-clean-014/taifun-clean-014_operating-instructions-manual_2525972028.webp)
7 | Maintenance
28
TAIFUN-CLEAN 014/015/016
7 Maintenance
WARNING
Risk of injury due to electric current
Conductive components can cause serious injury or death.
w
De-energise all components before you begin working.
WARNING
Risk of injury due to loose compressed air lines and connectors
Loose compressed air lines and connectors can cause severe injury.
w
Before starting any work, depressurise all components.
7.1 Maintenance Plan
Clean the TAIFUN-CLEAN unit whenever contaminated, however at least every
4 weeks.
Type of service
Service interval
Clean TAIFUN-CLEAN unit
As necessary, at least every 4 weeks
Table 5:
Maintenance plan TAIFUN-CLEAN
7.2 Maintenance of the Rotating Nozzles
If used as intended, the TAIFUN-CLEAN rotating nozzle is maintenance-free.
u
Check firm seating of the rotating nozzles in the TAIFUN-CLEAN device using only
the special mounting tool TCK7 (
Fig. 7, p. 29
).
Type of service
Service interval
Check rotating nozzles
As necessary, at least every 4 weeks
Table 6:
Maintenance plan rotating nozzles
1. Remove the cover disc, if present, by loosening the screws.
2. Set the mounting tool TCK7 on the rotating nozzle.
3. Turn the mounting tool TCK7 in a clockwise direction, until the rotating nozzle is
hand-tight.
4. If necessary, mount the cover disc again.