12
Operating Instructions for TAIFUN CLEAN
www.dr-escherich.com
Version 12/09
4.3
Compressed Air Rotation Nozzles Type TAIFUN-CLEAN
Check firm seating of the rotation nozzles in the TAIFUN-CLEAN profile only
with special tool TCK7. Place the tool on the rotor and turn in a clockwise
direction, until the rotor is hand-tight. Check the rotor seating regularly (s.
Maintenance Plan).
4.4
Suction Connection
Only for TAIFUN-CLEAN, 012, 014, 015! Attach suction hoses to the suction
connection ports of the TAIFUN-CLEAN (diameters s. Table 3) with hose clips.
Lay suction hoses to the adaptor, to the suction unit or the existing output air
system. Keep the hoses as short as possible. Avoid constrictions and radii
under three times the hose diameter, in order to minimise pressure drop.
Diameter of suction connection
port
TAIFUN-CLEAN 014
80 mm
TAIFUN-CLEAN 015
55 mm
TAIFUN-CLEAN 012
55 mm
Tab. 5
4.5 Electrical Cables and High Voltage Supply
The high voltage cables for supplying the ionizers are connected to the supply
unit via plug connection. Only adaptors suitable for the ionizers fitted may be
used for supplying the devices with high voltage. Detailed information is given in
the operating instructions for ionizers and high voltage adaptors and supply
units.