Manual Code 2600201
DOMIX45 – Rev.06 - 02.09.2014
9/32
1-
TECHNICAL FEATURES
Power supply (see machine rating plate)
208-240V AC or 110-127V AC
Mains frequency
50/60 Hz
Total absorbed power
25 VA
Installation category
ll
Environmental conditions
Indoor use only
Temperature range 5 ÷ 50°C (40 ÷ 120°F)
Relative humidity range 0 ÷ 95%
Hydraulic inlet connections
1/2”
Hydraulic outlet connections
16 mm
Maximum temperature at inlet
65°C (149°F)
Operating regulation range
2
÷
60°C (36
÷
140°F) pre/- 1%
Maximum inlet pressure
5 bar (72,5 psi)
Minimum inlet pressure
1 bar (14,5 psi)
Max ratio between the two entry pressures
1 : 5
Maximum batch
999,9 L; 99 lb + 15 oz; 999,9 lb
Dosing precision
± 1% (min batch: 5L)
Flow rate at 1 bar and 20°C
18 L/min (40 lb/min)
Flow rate at 5 bar and 20°C
40 L/min (88 lb/min)
Internal probe
Thermo-resistor PT1000 typeA
External probe
Thermo-resistor PT1000 typeA
Memory
80 programmable recipes
Supply fuse
250 V – T250 mA retarded @ 230 V
250 V – T630 mA retarded @ 115 V
Pump control fuse
250 V – F6,3 A
Protection Rating
IP 42
1.1.
DESCRIPTION
(See Fig. 1)
1.
Ball-taps with OR gasket.
2.
OR gasket-type unions for an easier installation.
3.
Stainless steel double mesh filters for water impurities.
4.
No-return valves.
5.
External temperature probe.
6.
Regulation knob for temperature setting, with reference scale.
7.
Supply plug, with fuse and spare, and remote pump control plug, with fuse and
spare.
8.
Display showing the water quantity selected, still to be delivered (during the dosing),
or already delivered (after pressing
[STOP/C]
).
9.
Display for the internal electronic thermometer and the set temperature.
10.
Display for the external electronic thermometer and the programs.
11.
Key to move from temperature to quantity and vice versa.
12.
[STOP/C]
and
[START]
keys.
13.
Delivery hose.
14.
By-pass connection.
15.
Membrane keyboard for the data entry.
16.
Series of function control lights.