A18
WATLOW PROGRAMMING
The Watlow temperature control can record 12 different menus. It must be programmed before use.
It will save its programs in case of power failure.
Each menu includes 3 "STEPS" and each step includes :
Symbol
•
temperature
SP
•
time
t
•
"EVENT"
E
(steam 0001, auto steam 0100, buzzer 0010 or
no event 0000)
To access the programming mode :
•
Press both arrows simultaneously for 5 seconds. Both lights light up to show that the
programming mode is working.
•
Unlock the read only mode (if necessary), press 12 and "CLOCK", LOC appears. Use the arrows
to get 0 and press "CLOCK" again. (To put back on read only mode, you have to have 1 before
pressing on "CLOCK".)
EXAMPLE 1 (preheat program)
-
For menu #1, we will program it so that we have a preheat time of 20 minutes at 400
°
F followed
by a 15 seconds buzzer.
Step #1
•
Press both arrows simultaneously for 5 seconds. Both lights light up to show that the
programming mode is working.
•
Select the program number (Ex : #1)
Suggested values
SP1 appears.
Use the arrows to adjust to the desired temperature
(400°F)
Press on the number of the menu to confirm
(ex. # 1)
t1 appears
Use the arrows to select the desired timing
(20:00)
Press on the number of the menu to confirm
(ex. # 1)
E1 appears
Use the arrows to select the appropriate code
(0000 for no event)
Press on the number of the menu to confirm
(ex. # 1)
Step #2
Suggested values
Summary of Contents for CA12G
Page 24: ...SECTION B DIMENSIONS ...
Page 26: ...B2 41 1 4 57 1 2 20 CA6G CA6G BASE ...
Page 28: ...B4 22 5 8 8 CA6G CA6G BASE ...
Page 30: ...B6 76 1 4 57 1 2 19 1 2 CA12G CA12G ...
Page 32: ...B8 7 1 2 23 1 4 CA12G CA12G ...
Page 34: ...B10 76 1 4 57 1 2 20 CAOP6G CAOP6G ...
Page 36: ...B12 8 22 5 8 CAOP6G CAOP6G ...
Page 38: ...B14 76 1 4 57 1 2 19 1 2 56 ENTRÉE DE GAZ 1 2 GAS INLET 1 2 CAOP12G CAOP12G ...
Page 40: ...B16 CAOP12G CAOP12G ...
Page 41: ...B17 23 1 4 7 1 2 CAOP12G CAOP12G ...
Page 42: ...SECTION C BURNER ADJUSTMENTS ...
Page 45: ...SECTION E COMPONENT PARTS ...
Page 48: ...E3 1 2 3 4 CAOP12G CAOP12G ...
Page 50: ...E5 3 4 5 6 7 8 1 2 10 H3 H1 H2 H4 X2 X4 X3 X1 9 CAOP12G CAOP12G ...
Page 52: ...E7 5 4 3 1 2 6 7 8 9 10 11 12 13 CAOP12G CAOP12G ...
Page 58: ...E13 1 2 3 4 5 6 7 CAOP12WG CAOP12G WATLOW ...
Page 61: ...SECTION F CONTROL PANELS ...
Page 76: ...SECTION G ELECTRIC SCHEMATICS ...