Dovre 525MF Installation Instructions And Operating Manual Download Page 14

See the chapter "Installation" for instructions on
removing and installing the inner plates.

The insulating vermiculite or chamotte inner
plates may develop hairline cracks, but this
does not affect their performance adversely.

Cast-iron inner plates last a long time if you
remove frequently the ash that can accumulate
behind them. If accumulated ash behind the
cast-iron plate is not removed, the plate will no
longer be able to dissipate the heat to the
surroundings and this may cause the plate to
warp or crack.

Never use the stove without the fire-resistant
inner plates.

Cleaning glass

Dirt clings less easily to well-cleaned glass. Proceed
as follows:

1. Remove dust and loose soot with a dry cloth.

2. Clean the glass with stove glass cleaner:

a. Apply stove glass cleaner to a kitchen sponge,

rub down the entire glass surface and give the
cleaning agent time to react.

b. Remove the dirt with a moist cloth or kitchen

tissue.

3. Clean the glass again with a normal glass cleaning

product.

4. Rub the glass clean with a dry cloth or kitchen

tissue.

Do not use abrasive or aggressive products to
clean the glass.

Wear household gloves to protect your hands.

If the glass in the appliance is broken or
cracked, it must be replaced before you can
use the appliance again.

Make sure that no stove window cleaner runs
between the glass and the cast-iron door.

Lubrication

Although cast-iron is slightly self-lubricating, you will
still need to lubricate moving parts frequently.

Lubricate the moving parts (such as guide
systems,hinge pins, latches and air slides) with
heat resistant grease that is available in the
specialist trade.

Touching-up the paint finish

Small areas of damaged paint finish can be touched
up with a spraying can of special heat-resistant paint
finish available from your supplier.

Checking the seal

Check whether the door sealing rope is still in good
condition and works well. The sealing rope is
subject to wear and will need to be replaced over
time.

Check the appliance for air leaks. Close any
chinks with stove sealant.

Allow the sealant to harden fully before lighting
the stove, as any moisture in the sealant will
form bubbles, resulting in a new air leak.

Exchange parts 525MF

5

1

1

6

4

7

3

4

2

09.20020.041

Pos.

Part number

Description Quantity

1

03.77518.000

rear inner
plate

1

2

03.56333.000

grid holder 1

3

03.77411.002

fire basket 1

4

03.77517.000

side inner
plate

2

5

03.76178.000

baffle plate 1

6

03.61116.000

grate

1

7

03.05238.000

ash pan

1

14

Subject to change because of technical improvements

Summary of Contents for 525MF

Page 1: ...HOUTKACHEL INSTALLATION INSTRUCTIONS AND OPERATING MANUAL WOOD STOVE INSTALLATION ET MODE D EMPLOI POELE A BOIS EINBAUANLEITUNG UND GEBRAUCHSANWEISUNG HOLZ FEUERST TTE INSTRUCCIONES DE INSTALACI N Y...

Page 2: ...9 Fuel 9 Lighting 9 Burning wood 10 Burning brown coal briquettes 11 Burning anthracite coal 11 Controlling combustion air 11 Extinguishing the fire 12 Removing ashes 12 Fog and mist 13 Solving proble...

Page 3: ...RE cannot be held liable for any problems or damage resulting from incorrect installation Observe the following safety regulations when installing and using the appliance In this manual you can read h...

Page 4: ...ance is installed If ventilation is insufficient combustion will be incomplete resulting in toxic gases being produced and spread through the room See the chapter Installation requirements for more in...

Page 5: ...oxygen This air is supplied via adjustable air inlets from the area in which the stove is installed The combustion will be incomplete in case of insufficient ventilation which results in toxic gases...

Page 6: ...becomes warm during use a glove has been supplied which you may use to protect your hand The appliance is suitable for connection to outside air supply The appliance comes standard with a connection...

Page 7: ...hamber improving combustion and they can withstand burning anthracite coals Cast iron inner plates protect the combustion chamber and dissipate heat to the surroundings 5 1 1 6 4 7 3 4 2 09 20020 041...

Page 8: ...0008 007 1 2 3 4 5 Preparing the outside air connection If the appliance is installed in a room without sufficient ventilation you can install the connecting kit on the appliance for the supply of out...

Page 9: ...t least 2 years Saw the wood to size and split it while it is still fresh Fresh wood is easier to split and split wood dries more easily Store the wood under a roof where the wind has free access Do n...

Page 10: ...y air inlet of the appliance see the following figure 5 Allow the fire develop into a good blaze until there is glowing bed of charcoal You can then add fuel and adjust the appliance see the chapter S...

Page 11: ...l briquettes on the charcoal bed 4 Close the door 5 Regularly remove ashes from the stove base riddling the grate Use the cold handle to operate the riddling rod Burning anthracite coal Always close t...

Page 12: ...pen the primary air inlet for the time being if the air supply by the secondary air inlet is inadequate or if you want to fan the fire It is better to add a small amount of logs regularly than to add...

Page 13: ...e your chimney checked and maintained At the beginning of the heating season have the chimney swept by an expert During the heating season and after the chimney has not been used for a long time have...

Page 14: ...ass in the appliance is broken or cracked it must be replaced before you can use the appliance again Make sure that no stove window cleaner runs between the glass and the cast iron door Lubrication Al...

Page 15: ...g s 3 9 g s Flue gas temperature measured in the measurement section 288 C 298 C 299 C Temperature measured at the appliance outlet 396 C 385 C 402 C Minimum draught 12 Pa 12 Pa 12 Pa CO emission 13...

Page 16: ...Appendix 2 Measurements 525MF 09 20020 108 16 Subject to change because of technical improvements...

Page 17: ...ible material 2 Incombustible material thickness 100 mm Please note To guarantee the flow of combustion air when no outside air connection is provided the distance from the outside air connection coll...

Page 18: ...reproof protective plate A B B 09 20002 004 Minimal dimensions of fireproof protective plate A mm B mm Din 18891 500 300 Germany 500 300 Finland 400 100 Norway 300 100 18 Subject to change because of...

Page 19: ...osit hermetically tight no chinks Chimney stack incorrect Sufficiently high above the roof no obstacles in the vicinity Air inlets set incorrectly Open the air inlets completely Stove connected to the...

Page 20: ...ction diameter 15 connection to 8 height 5 sweep 13 Chinks in appliance 14 Clean glass 14 Cleaning appliance 13 Coal ash content 9 Combustible material distance from 17 Connection measurements 16 Conn...

Page 21: ...cast iron 7 chamotte 7 Inner plates fire resistant remove 7 Installation measurements 16 K Kindled fire 9 Kindling 19 L Lighting 9 Lubricant 14 Lubricate 14 M Maintenance chimney 13 clean glass 14 cle...

Page 22: ...supply of outside air 8 rule of thumb 5 Ventilation louvre 5 Vermiculite inner plates 7 W Walls fire safety 5 Warning chimney fire 4 9 12 combustible materials 4 fireproof inner plates 9 glass broken...

Reviews: