![Dovre 300CB Installation Instructions And Operating Manual Download Page 34](http://html1.mh-extra.com/html/dovre/300cb/300cb_installation-instructions-and-operating-manual_2525183034.webp)
Appendix 1: Technical Data
Model
300CB
340CB
342CB
Nominal output
9 kW
10 kW
10.5 kW
Flue connection (diameter)
125 mm
125 mm
125 mm
Weight
115 kg
160 kg
180 kg
Recommended fuel
Wood
Wood
Wood
Fuel property, max. length
60 cm
60 cm
60 cm
Mass flow of flue gasses
5.8 g/s
7.0 g/s
7.5 g/s
Temperature increase measured in the measuring
section
301
℃
208 °C
196 °C
Temperature measured at appliance exit
384
℃
306 °C
280 °C
Minimum draught
12 Pa
12 Pa
12 Pa
CO emission (13%O
2
)
0.08 %
0.10 %
0.10 %
NOx emission (13% O
2
)
84 mg/Nm³
76 mg/Nm³
82 mg/Nm³
CnHm emission (13%O
2
)
52 mg/Nm³
142 mg/Nm³
127 mg/Nm³
Particulate emission
21 mg/Nm³
32 mg/Nm³
27 mg/Nm³
Efficiency
79.9 %
83.1 %
83.5 %