Dovre 2000CBBS Installation Instructions & Operating Manual Download Page 15

2000CB

                                                            15                                                 

03.27997.000

 

Bijlage 1     :        technische gegevens  
Annexe 1   :        données techniques 
Annex 1     :        technical data sheet 
Anlage 1    :        technischen Daten 

Model / Modèle / Modell 

2000CB/GL-BS 

Nominaal vermogen 
Puissance nominale 
Nominal heat output 
Nominalleistung 

8 kW  (10 kW max) 

Aanbevolen brandstoffen 
Combustibles conseillés 
Advised combustibles 
Empfohlene Brennstoffe 

Hout 
Bois 
Wood 
Holz 

Maximale lengte houtblokken 
Longueur maximale des bûches 
Maximal length of logs 
Maximal Länge der Holzblocken 

40 cm 

Schoorsteenaansluiting 
(diameter) 
Raccordemant cheminée 
(diamètre) 
Flue connection (diametre) 
Schornsteinanschluss (Diameter) 

150 mm 

Massadebiet van rookgassen  
Débit des fumées  
Flue gas mass flow  
Abgasmassenstrom 

 

11.4 g/s 

Rookgastemperatuur  
Température des fumées  
Flue gas temperature  
Abgasstutzentemperatuur 

 

397 °C 

Minimum trek 
Dépression minimal 
Minimum draught 
Mindesförderdruck  

0.11 mbar 

Gewicht   /  Poids  /  Weight 

125 kg 

Summary of Contents for 2000CBBS

Page 1: ...INSTALLATIEVOORSCHRIFTEN EN GEBRUIKSAANWIJZING INSTALLATION ET MODE D EMPLOI INSTALLATION INSTRUCTIONS AND OPERATING MANUAL EINBAUANLEITUNG UND GEBRAUCHSANWEISUNG INBOUWHAARD FOYER FIREPLACE KAMINEINS...

Page 2: ...moval 38 4 6 Extinguishing the fire 38 4 7 Weather conditions 39 5 Maintenance 39 Annex 1 Technical data sheet 52 Annex 2 Dimensions 53 Inhalt pag Vorwort 40 1 Einleitung 40 2 Sicherheit 40 3 Montagev...

Page 3: ...ke the long term and trouble free functioning of your heater for granted Please consult an expert when installing and connecting the heater The manufac turer cannot be held liable for problems caused...

Page 4: ...ught is caused by environmental phenomena such as wind It is prohibited to connect several heaters to one chimney for instance the central heating boiler unless local or national regulations allow thi...

Page 5: ...pt the combustion process and cause the smoke flow through the chimney to be interrupted which may lead to smoke emissions into the room Mainly in case of a fireplace together with the combustion gase...

Page 6: ...e and the walls around it must not contain electric wires The appliance shall be installed on floors with an adequate load bearing capacity Under the appliance Under the appliance any combustible mate...

Page 7: ...t the height of the leg on the holder with bolt M8x50 nut M8 and both collars 8x 25 Fix the adjustment bolts under the legs These will allow to adjust the fireplace level 3 1 4 Combustible material ro...

Page 8: ...either horizon tally or vertically Fix the flue collar on the smoke dome with 2 bolts M6x30 2 nuts M6 and 4 collars 6x 12 Assure proper sealing with kit or paste 3 2 3 Installation of the ashtray if...

Page 9: ...pening is 250 cm The grids may be installed on all sides It is important that air flows freely into the convection chamber If you use an air vent to convey outside air into the convection chamber reme...

Page 10: ...other auxiliary material such as steel it will not function as a heat bridge The picture on the next page shows an example of fireplace installation within com bustible material 3 4 Finishing When the...

Page 11: ...e wall Convection area Fresh air inlet Fireproof floor Combustible floor Convection air inlet Insulation if necessary Convection Air outlet Opening against eventual pressu re buildup Stainless steel p...

Page 12: ...than twenty pe r cent moisture Wet logs are unsuitable for burning as they do not produce enough heat and all of the energy is lost in the process of evaporation Moreover the burning of wet wood cause...

Page 13: ...cause tar and creosote to deposit in the chimney after a long pe riod of time Tar and creosote are highly combustible substances Thicker layers of these substances might catch fire when the t emperatu...

Page 14: ...glass can be cleaned with a number of glass cleaning products available on the market Your installer can also supply you with appropriate products However never use abrasive or corrosive cleaning pro...

Page 15: ...e Hout Bois Wood Holz Maximale lengte houtblokken Longueur maximale des b ches Maximal length of logs Maximal L nge der Holzblocken 40 cm Schoorsteenaansluiting diameter Raccordemant chemin e diam tre...

Page 16: ...2000CB 16 03 27997 000 Bijlage 2 afmetingen Annexe 2 dimensions 2000CB GL 2000CB BS Annex 2 dimensions Anlage 2 Abmessungen...

Page 17: ...2000CB 17 03 27997 000...

Page 18: ...ntinuous product improvement specifications of the delivered product may differ from the con tent of this booklet without further notice Im Rahmen kontinuerlicher Produktverbesserung k nnen Specifikat...

Page 19: ......

Page 20: ...E O E...

Reviews: