SECTION 7F – AIR-CONTROLLED

TROUBLESHOOTING

Pump will not run or runs slowly.

1.  Check air inlet screen and air filter for debris.
2.  Check for sticking air valve, flush air valve in solvent.
3. Check for worn out air valve. If piston face in air valve is 

shiny instead of dull, air valve is probably worn beyond 
working tolerances and must be replaced.

4. Check center block Glyd™ rings. If worn excessively, they 

will not seal and air will simply flow through pump and out 
air exhaust. Use only Wilden Glyd™ rings as they are of 
special construction and ISO 15-5 wt oil with arctic char-
acteristics.

5.  Check for rotating piston in air valve.
6. Check type of lubricant being used. A higher viscosity 

oil than suggested may cause the piston to stick or run 
erratically. Wilden suggests the use of a hydraulic oil with 
arctic characteristics (ISO 15-5 wt).

Pump runs but little or no product flows.

1. Check for pump cavitation; slow pump speed down to 

match thickness of material being pumped.

2. Check for sticking ball checks. If material being pumped 

is not compatible with pump elastomers, swelling may 

occur. Replace ball checks and o-rings with proper elas-
tomers.

3. Check to make sure all suction connections are air tight, 

especially clamp bands around intake balls.

Pump air valve freezes.

Check for excessive moisture in compressed air. Either 
install dryer or hot air generator for compressed air.

Air bubbles in pump discharge.

1.  Check for ruptured diaphragm.
2. Check tightness of clamp bands, especially at intake 

manifold.

Product comes out air exhaust.

1.  Check for diaphragm rupture.
2.  Check tightness of piston plates to shaft.

Pump rattles.

1.  See E9 Troubleshooting Guide.
2.  Create false discharge head or suction lift.

SECTION 7G – ACCU-FLO™

TROUBLESHOOTING

Pump will not run.

1. Check for pressurized air at the inlet. (Min. 3.1 bar [45 
psig].)
2.  Check air inlet and filter for debris.
3. Connect a test lamp to the two wires which run to pump 

and ensure that the lamp cycles on and off.

4. Make sure that the air valve manual override (small red 

knob on front of valve) is switched to the “0” position.

5. Check pilot pressure vent at the top of the operator/coil 

assembly to ensure that it is not clogged.

6. Check for a worn out air valve. If air continually blows out 

the exhaust in very large quantities, the air valve seals 
may be worn beyond their ability to function. In this case, 
the valve must be replaced.

NOTE: Before the valve is scrapped, it is possible that it may 
be saved by completely disassembling the valve, cleaning all 
components and relubricating the valve.

Pump runs but little or no fluid comes out.

1.  Check that the discharge isolation valve is not closed.
2. Check that the electronic signal is slow enough that the 

pump is able to complete each physical stroke before 
it is signaled to change direction. The time required to 
complete the stroke is determined by a variety of factors 
which include fluid viscosity and head pressure. The shaft 
can be viewed if the muffler is removed to verify that the 
pump is stroking.

3. Check for pump cavitation; slow pump speed down to 

match the thickness of the material being pumped.

4. Check for sticking ball check valves. If the material being 

pumped is not compatible with the pump elastomers, 
swelling may occur. Replace ball check valves and o-ring 
with the proper elastomers.

5. Check to make sure that all suction connections are air 

tight, and that the clamp bands are properly tightened.

Pump air passages blocked with ice.

Check for excessive moisture in compressed air line. As 

the air expands out the exhaust during the operation of 
the pump, water vapor entrapped in the compressed air 
can freeze and block the air passageways in the pump. 
If this occurs, it may be necessary to install a coalescing 
filter, an air dryer, or a hot air generator for the compressed 
air.

Air bubbles in pump discharge.

1.  Check for ruptured diaphragm.
2. Check tightness of clamp bands, and the integrity of the

o-rings, especially at intake manifold.

Product comes out air exhaust.

1.  Check for diaphragm rupture.
2.  Check tightness of piston plates to shaft.

Pump rattles.

1.  See E9 Troubleshooting Guide.
2.  Create false discharge head or suction lift.

Solenoid buzzes or solenoid burnout.

1.  Incorrect voltage, faulty or dirty solenoid.

Solenoid valve fails to shift electrically but shifts with 
manual override.

1.  Incorrect voltage, defective coil or wiring.

Solenoid valve fails to shift electrically or with manual 
override.

1. Inadequate air supply, contamination, inadequate or 

improper lubrication, mechanical binding in the valve.

Valve shifts but fails to return.

1.  Broken spring, mechanical binding.

Excessive leaking from air valve vent.

1.  Worn seals in air valve.

Summary of Contents for Wilden Original A4

Page 1: ...EOM S i m p l i f y y o u r p r o c e s s Engine e ri n g Opera ti o n Maint e n a n ce Original Series METAL Pumps T4 A4 WIL 10260 E 02 REPLACES EOM T4 A4M 4 05...

Page 2: ...ontrolled 11 B A4 METAL Accu Flo 11 SECTION 7 INSTALLATION OPERATION A Installation Turbo Flo Suggested Installation Drawing 12 B Operating and Maintenance 13 C Principles Behind Accu Flo Pumps 14 D I...

Page 3: ...ump should be disconnected and all air pressure allowed to bleed from pump Disconnect all intake discharge and air lines Drain the pump by turning it upside down and allowing any fluid to flow into a...

Page 4: ...09 Spark free BSPT Wil Gard II 220V 0113 Stallion internals spark free BSPT 0120 Saniflo FDA Wil Gard II 110V 0124 Saniflo FDA Accu Flo 24 V DC x proof coil Intl PTB approved 0127 Saniflo FDA Accu Flo...

Page 5: ...the liquid chamber see shaded area FIGURE 2 When the pressurized diaphragm diaphragm A reaches the limit of its discharge stroke the air valve redirects pressurized air to the back side of diaphragm...

Page 6: ...ID INLET 32 mm 1 1 4 BSP FNPT LIQUID DISCHARGE 19 mm 3 4 BSP FNPT AIR EXHAUST A B C D E F G H J K L M N P R S T DIMENSIONS ITEM METRIC mm STANDARD inch A 391 15 4 B 63 2 5 C 219 8 6 D 442 17 4 E 285 1...

Page 7: ...FNPT AIR INLET A F G H J B C D E 51 mm 2 TRI CLAMP 51 mm 2 TRI CLAMP 13 mm 1 2 BSP FNPT AIR INLET 19 mm 3 4 BSP FNPT AIR EXHAUST A F G H J K L B C D E DIMENSIONS ITEM METRIC mm STANDARD inch A 391 15...

Page 8: ...o that daily operation parameters will fall in the center of the pump performance curve LPM Water Discharge Flow Rates SECTION 5B PERFORMANCE CURVES T4 METAL ULTRA FLEX FITTED Height 452 mm 17 4 Width...

Page 9: ...ied so that daily operation parameters will fall in the center of the pump performance curve LPM Water Discharge Flow Rates SECTION 5D PERFORMANCE CURVES T4 METAL PTFE FITTED Height 442 mm 17 4 Width...

Page 10: ...mm 1 2 1 Displacement per stroke was calculated at 4 8 bar 70 psig air inlet pressure against a 2 bar 30 psig head pressure Example To pump 98 4 lpm 26 gpm against a discharge pressure head of 2 7 ba...

Page 11: ...ute See dot on chart Caution Do not exceed 8 6 bar 125 psig air supply pressure Flow curves are for optimal speed conditions only The optimal speed is that speed which provides the maximum flow under...

Page 12: ...40 psig requires 4 1 bar 60 psig 18 7 Nm3 h 11 scfm air consumption and a pump speed of 115 strokes minute See dot on chart Caution Do not exceed 8 6 bar 125 psig air supply pressure Flow curves are...

Page 13: ...ation atmospheric pressure and pipe friction loss all affect the amount of suction lift your pump will attain Suction lift curves are calibrated for pumps operating at 1 000 305 m above sea level This...

Page 14: ...ION Selecting a site that is well within the pump s suction lift capability will assure that loss of prime troubles will be eliminated In addition pump efficiency can be adversely affected if proper a...

Page 15: ...records make it possible to identify pumps that are poorly suited to their applications MAINTENANCE AND INSPECTIONS Since each application is unique maintenance schedules may be different for every pu...

Page 16: ...rical power is off THE MODEL A4 WILL PASS 4 8 mm 3 16 SOLIDS THE M4 STALLION WILL PASS 13 mm 1 2 SOLIDS WHENEVER THE POSSIBILITY EXISTS THAT LARGER SOLID OBJECTS MAY BE SUCKED INTO THE PUMP A STRAINER...

Page 17: ...every 50 million cycles Continuous lubrication with a compatible oil is not harmful and will provide longer seal life but it may flush all grease out of the unit A red button on the side of the air v...

Page 18: ...e If air continually blows out the exhaust in very large quantities the air valve seals may be worn beyond their ability to function In this case the valve must be replaced NOTE Before the valve is sc...

Page 19: ...4 outlet and is designed for flows up to 81 gpm 307 lpm The model T4 is available in aluminum cast iron or 316 stainless steel wetted parts The air valve is manufactured of brass PTFE coated brass ni...

Page 20: ...h or by rotat ing the diaphragm by hand remove the diaphragm assembly Step 4 Figure 4 Remove the discharge valve balls and seats from the liquid chambers and inspect for nicks gouges chemical attack o...

Page 21: ...haft which remains connected to the opposite side diaphragm assembly Figure 9B Repeat disassembly instructions for the opposite liquid chamber Inspect diaphragm assembly and shaft for signs of wear or...

Page 22: ...is preventing the air valve piston from moving freely Also remove and clean the air valve screen P N 04 2500 03 If the air valve piston does not move freely after the above cleaning the air valve shou...

Page 23: ...inder ports is maintained see Figure D Reinstall air valve to center block of pump Tighten per the torque specification GLYD RING REPLACEMENT When the Glyd rings become worn they will no longer seal a...

Page 24: ...tions on this page The following tips will assist in the assembly process Clean the inside of the center section shaft bushing to ensure no damage is done to new seals Stainless bolts should be lubed...

Page 25: ...ape should overlap approximately 13 mm 1 2 Proceed to install the PTFE tape on the remaining diaphragm The Wilden T4 cast iron pumps require PTFE gasket tape on the liquid chambers P N 04 9502 99 Othe...

Page 26: ...24 WILDEN PUMP ENGINEERING LLC WIL 10260 E 02 SECTION 9A EXPLODED VIEW PARTS LISTING T4 METAL AIR OPERATED RUBBER TPE OR ULTRAFLEX FITTED...

Page 27: ...03 04 5000 03 04 5000 02 04 5000 02 04 5000 03 04 5000 03 22 Clamp Band Large 2 04 7300 08 04 7330 08 04 7300 03 04 7330 03 04 7300 08 04 7330 03 04 7300 03 04 7330 08 04 7330 03 04 7300 03 70 04 7330...

Page 28: ...26 WILDEN PUMP ENGINEERING LLC WIL 10260 E 02 PTFE Assembly SECTION 9B EXPLODED VIEW PARTS LISTING T4 METAL AIR OPERATED PTFE FITTED...

Page 29: ...03 70 23 Clamp Band Small 4 04 7100 03 04 7100 03 04 7100 03 04 7100 03 04 7100 03 70 04 7100 03 70 24 Discharge Manifold 1 04 5020 01 04 5020 01 04 5020 03 04 5020 02 04 5020 03 70 04 5020 03 70 25 I...

Page 30: ...28 WILDEN PUMP ENGINEERING LLC WIL 10260 E 02 SECTION 9C EXPLODED VIEW PARTS LISTING A4 METAL ACCU FLO...

Page 31: ...ifold 1 04 5020 01 04 5020 04 04 5020 03 04 5020 02 04 5020 01 04 5020 04 04 5020 03 04 5020 02 18 Inlet Housing 1 04 5080 01 04 5080 04 04 5080 03 04 5080 02 04 5080 01 04 5080 04 04 5080 03 04 5080...

Page 32: ...1120 50 N A N A Wil Flex 04 1010 58 N A 04 1080 58 04 1120 58 N A N A Sani ex 04 1010 56 N A 04 1080 56 04 1120 56 N A N A Fluoro Seal N A N A N A N A 04 1200 34 N A PTFE 04 1010 55 N A 04 1080 55 N A...

Page 33: ...4 22 4 8 40 40 40 32 00 2110 99 155 60 120 110 4 8 08 08 06 840 NEMA 7 UL CSA Voltage 10 Current A AC AC DC Power W DC Resistivity Part Number 60 Hz 50 Hz 10 Inrush Holding 00 2110 99 153 12 24 22 7 6...

Page 34: ...32 WILDEN PUMP ENGINEERING LLC WIL 10260 E 02...

Page 35: ...comes rst Failure due to normal wear misapplication or abuse is of course excluded from this warranty Since the use of Wilden pumps and parts is beyond our control we cannot guarantee the suitability...

Reviews: