![Dover Wilden Advance Pro-Flo V PV400 Series Engineering, Operation & Maintenance Download Page 12](http://html1.mh-extra.com/html/dover/wilden-advance-pro-flo-v-pv400-series/wilden-advance-pro-flo-v-pv400-series_engineering-operation-and-maintenance_2525057012.webp)
WILDEN PUMP & ENGINEERING, LLC
10
WIL-11100-E-05
P E R F O R M A N C E
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specifi ed so that daily operation
parameters will fall in the center of the pump performance curve.
PV400 ALUMINUM
RUBBER-FITTED
Height .................................594 mm (23.4")
Width ..................................343 mm (13.5")
Depth .................................. 310 mm (12.2")
Est. Ship Weight ....Aluminum 33 kg (72 lbs)
Air Inlet ...................................19 mm (3/4")
Inlet ..................................... 38 mm (1-1/2")
Outlet .................................. 38 mm (1-1/2")
Suction Lift ...................... 5.2 m Dry (17.0')
9.5 m Wet (31.2')
Displacement/Stroke ...... 1.17 l (0.31 gal.)
1
Max. Flow Rate ........... 405 lpm (107 gpm)
Max. Size Solids ................. 7.9 mm (5/16")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.1 bar (30 psig) head pressure.
Example:
To pump 57 lpm (15 gpm)
against a discharge pressure head of
2.6 bar (38 psig) requires 2.8 bar
(40 psig) and 17 Nm
3
/h (10 scfm) air
consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specifi ed so that daily operation
parameters will fall in the center of the pump performance curve.
PV400 ALUMINUM
TPE-FITTED
Height .................................594 mm (23.4")
Width ..................................343 mm (13.5")
Depth .................................. 310 mm (12.2")
Est. Ship Weight ....Aluminum 33 kg (72 lbs)
Air Inlet ...................................19 mm (3/4")
Inlet ......................................38 mm (1-1/2")
Outlet ...................................38 mm (1-1/2")
Suction Lift ..................... 5.2 m Dry (16.9')
9.5 m Wet (31.2')
Displacement/Stroke ......1.21 l (0.32 gal.)
1
Max. Flow Rate ............ 443 lpm (117 gpm)
Max. Size Solids ................. 7.9 mm (5/16")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.1 bar (30 psig) head pressure.
Example:
To pump 148 lpm (39 gpm)
against a discharge pressure head of
4.3 bar (62 psig) requires 5.5 bar (80 psig)
and 68 Nm
3
/h (40 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.