![Dover WILDEN ACCUFLO A8 Engineering, Operation & Maintenance Download Page 6](http://html.mh-extra.com/html/dover/wilden-accuflo-a8/wilden-accuflo-a8_engineering-operation-and-maintenance_2525059006.webp)
4
WILDEN PUMP & ENGINEERING CO.
SECTION 4A
DIMENSIONAL DRAWING
WILDEN MODEL T8 PLASTIC CHAMP
S
A
B
C
D
E
M
L
K
J
N
P
R
G
F
H
CL
AIR INLET
AIR EXHAUST
FLANGE
150 POUND CLASS
19.0 mm (3/4") FNPT
19.0 mm (3/4") FNPT
50.8 mm (2") I.D.
DIMENSIONS – T8 CHAMP (PLASTIC)
ITEM
METRIC (mm) STANDARD (inch)
A
491.4
19 11/32
B
77.0
3 1/32
C
693.0
27 9/32
D
770.0
30 5/16
E
455.6
17 7/16
F
88.9
3 1/2
G
344.5
13 9/16
H
332.6
13 3/32
J
386.6
15 7/32
K
306.4
12 1/16
L
228.6
9
M
254.0
10
N
14.3
9/16
METRIC (mm) STANDARD (inch)
P
60.3 RAD
2 3/8 RAD.
R
76.2 RAD.
3 1/32 RAD.
S
19.8 DIA
25/32 DIA..
Tee section is designed to accommodate both
standard and metric pipe connections.
SECTION 4B
DIMENSIONAL DRAWING
WILDEN MODEL A8 PLASTIC ACCU-FLO™
0
1
A
1/2" FNPT
AIR EXHAUST
FLANGE
AIR INLET
B
C
D
E
F
G
H
J
K
L
M
N
P
R
S
T
19.0 mm (3/4") FNPT
19.0 mm
(3/4") FNPT
DIMENSIONS – A8 ACCU-FLO™ (PLASTIC)
ITEM
METRIC (mm) STANDARD (inch)
A
491.4
19 11/32
B
77.0
3 1/32
C
409.6
16 1/8
D
693.0
27 9/32
E
770.0
30 5/16
F
88.9
3 1/2
G
344.5
13 9/16
H
332.6
13 3/32
J
86.5
3 3/32
K
386.6
15 7/32
L
306.4
12 1/16
M
228.6
9
N
254.0
10
P
14.3
9/16
METRIC (mm) STANDARD (inch)
R
60.3 RAD
2 3/8 RAD.
S
76.2 RAD.
3 1/32 RAD.
T
19.8 DIA.
25/32 DIA.
Tee section is designed to accommodate both