![Dover WILDEN ACCUFLO A8 Engineering, Operation & Maintenance Download Page 30](http://html.mh-extra.com/html/dover/wilden-accuflo-a8/wilden-accuflo-a8_engineering-operation-and-maintenance_2525059030.webp)
28
WILDEN PUMP & ENGINEERING CO.
28
WILDEN PUMP & ENGINEERING CO.
SECTION 10A
ELASTOMER OPTIONS
T8 PLASTIC
Traditional
Ultra-Flex™
Valve Seat*
Manifold
Valve Ball
Material
Diaphragms (2)
Diaphragms (2)
O-Rings (4)
O-Rings (4)
(4)
Polyurethane
08-1010-50
N/A
08-1200-50-500
08-1300-50-500
08-1080-50
Neoprene
08-1010-51
08-1020-51
N/A
N/A
08-1080-51
Buna-N
®
08-1010-52
08-1020-52
08-1200-52-500
08-1300-52-500
08-1080-52
Nordel
®
(EPDM)
08-1010-54
08-1020-54
N/A
N/A
08-1080-54
Viton
®
08-1010-53
08-1020-53
N/A
N/A
08-1080-53
Saniflex™
08-1010-56
N/A
N/A
N/A
08-1080-56
Teflon
®
PTFE
08-1010-55
3
N/A
N/A
N/A
08-1080-55
Neoprene Backup
08-1060-51
N/A
N/A
N/A
N/A
Wil-Flex™
08-1010-58
N/A
N/A
N/A
08-1080-58
Teflon
®
Encap. (Viton
®
)
N/A
N/A
08-1200-60-500
08-1300-60-500
N/A
NOTES
Teflon
®
-encapsulated Viton
®
O-rings, P/N 08-1200-60-500 and P/N 08-1300-60-500, are standard on all Teflon
®
-fitted pumps.
Teflon
®
diaphragm, P/N 08-1010-55, must be used with Neoprene back-up diaphragms, P/N 08-1060-51.
*NOTE: Rubber valve seats do not require an O-ring.
SECTION 10B – ACCU-FLO™
ELECTRICAL REFERENCE
NEMA 4 / UL / CSA
Voltage ±10%
Current (A)
AC
AC
DC
Power (W)
DC
Resistivity
Part Number
60 Hz
50 Hz
±10%
Inrush
Holding
(
Ω
)
00-2110-99-150
24
48
44
4.8
.20
.20
.20
121
00-2110-99-151
12
24
22
4.8
.40
.40
.40
32
00-2110-99-155
60
120
110
4.8
.08
.08
.06
840
NEMA 7 / UL / CSA
Voltage ±10%
Current (A)
AC
AC
DC
Power (W)
DC
Resistivity
Part Number
60 Hz
50 Hz
±10%
Inrush
Holding
(
Ω
)
00-2110-99-153
12
24
22
7
.60
.55
.32
19
00-2110-99-154
24
48
44
7
.30
.30
.18
75
00-2110-99-156
60
120
110
7
.12
.13
.06
475
INTERNATIONAL EXPLOSION PROOF / CENELEC / PTB FILE # EX-91.C.2027
Current (A)
DC Voltage ±10%
Power (W)
Resistivity
Part Number
±10%
Inrush
Holding
(
Ω
)
00-2110-99-157
24
3.3
.135
.135
177