NOTE: In the event of a power failure, the shut-off
valve should be closed, if the restarting of the pump is
not desirable once power is regained.
AIR-OPERATED PUMPS: To stop the pump from
operating in an emergency situation, simply close
the shut-off valve (user-supplied) installed in the air
supply line. A properly functioning valve will stop the
air supply to the pump, therefore stopping output. This
shut-off valve should be located far enough away from
the pumping equipment such that it can be reached
safely in an emergency situation.
NEEDLE VALVE
AIR SHUT-OFF VALVE
FOOTPAD
COMBINATION
FILTER & REGULATOR
SUCTION
MUFFLER
FLEXIBLE
CONNECTION
FLEXIBLE
CONNECTION
GAUGE
(OPTIONAL)
EQUALIZER
SURGE DAMPENER
(OPTIONAL)
SHUT-OFF
VALVE
DISCHARGE
WILDEN PUMP & ENGINEERING, LLC
18
WIL-11610-E-02
S U G G E S T E D I N S T A L L A T I O N
This illustration is a generic
representation of an air-operated
double-diaphragm pump.