The Pro-Flo X™ air distribution system with the
revolutionary Efficiency Management System (EMS)
offers flexibility never before seen in the world of
AODD pumps. The
patent-pending EMS
is simple and easy
to use. With the
turn of an integrated
control dial, the operator can select the optimal
balance of flow and efficiency that best meets the
application needs. Pro-Flo X™ provides higher
performance, lower
operational costs
and flexibility that
exceeds previous
industry standards.
Pro-Flo X
TM
Operating Principle
S e c t i o n 5 B
Turning the dial
changes the
relationship
between air inlet
and exhaust
porting.
Each dial setting
represents an
entirely different
flow curve.
Pro-Flo X™ pumps
are shipped from
the factory on
setting 4, which
is the highest
flow rate setting
possible.
Moving the dial
from setting 4
causes a decrease
in flow and an even
greater decrease in
air consumption.
When the air
consumption
decreases more
than the flow
rate, efficiency
is improved and
operating costs
are reduced.
$
$
$