Dover PSG Wilden PRO-FLO P1500 Engineering Operation & Maintenance Manual Download Page 5

 

WIL-11160-E-10  

P1500 Bolted Plastic 

 

SECTION 2 

NOTE:

 Most elastomeric materials use colored dots for identification.    

NOTE:

 Not all models are available with all material options

 

 

MATERIAL CODES

 

MODEL 

P1500 = PRO-FLO

®

 PLASTIC 

 

WETTED PATH 

K= PVDF 
P = POLYPROPYLENE 
 

OUTER PISTON  

K = PVDF 
P = POLYPROPYLENE 
S = STAINLESS STEEL 
Z = NO OUTER PISTON 
 

AIR CHAMBERS 

P = POLYPROPYLENE  

 
CENTER BLOCK 

P = POLYPROPYLENE  

 

AIR VALVE 

P = POLYPROPYLENE  

 

DIAPHRAGMS 

FWL = SANITARY WIL-FLEX™, IPD 

[SANTOPRENE

®

 (TWO BLACK 

DOTS)]  

FSL = FULL-STROKE SANITARY  
            SANIFLEX

™ 

IPD [HYTREL

® 

(CREAM)] 

SSL = FULL-STROKE SANIFLEX

 

            IPD [HYTREL

®

 (CREAM)] 

TEU = PTFE W/EPDM BACKUP  
           (WHITE) 
TNU = PTFE W/NEOPRENE 
            BACKUP (WHITE) 
TSS = FULL-STROKE PTFE 

W/SANIFLEX™ BACK-UP 

TSU = PTFE W/SANIFLEX™   
           BACK-UP (WHITE) 
TWS = FULL-STROKE PTFE 
            W/WIL-FLEX™ BACKUP 
WWL= WIL-FLEX™ IPD [SANTOPRENE

®

 

(THREE BLACK DOTS)] 

ZGS = GEOLAST

®

, EZ-INSTALL (BLACK) 

ZPS = POLYURETHANE,  

EZ-INSTALL (CLEAR) 

ZSS = SANIFLEX™, EZ-INSTALL 

[HYTREL

®

 (CREAM)] 

ZWS = WIL-FLEX™, EZ-INSTALL 

[SANTOPRENE

®

 (THREE BLACK 

DOTS)] 

 

VALVE BALLS 

TF = PTFE (WHITE) 
 

VALVE SEATS 

K= PVDF 
 

VALVE SEATS & MANIFOLD  
O-RING 

TV = PTFE ENCAP, FKM 
 

 

SPECIALTY CODES

 

0100 Wil

-

Gard II™ 110V

  

0102 Wil

-

Gard II™ sensor wires Only 

0103 Wil

-

Gard II™ 220V 

0206 PFA-coated hardware, Wil-Gard II™ sensor wires ONLY 

0480 Pump Cycle Monitor (sensor & wires) 

 

 

0483 Pump Cycle Monitor (module, sensor & wires) 

0485 Pump Cycle Monitor (module, sensor & wires), DIN flange 

0502 PFA coated hardware 

0504 DIN flange 

0506 DIN flange, PFA coated hardware 

0604 DIN flange, Wil-Gard II™ 220V 

 

0608 PFA-coated hardware, Wil-Gard II™ 220V 

0690 Center-Ported ANSI/DIN Combo 

0691 Center-Ported, ANSI/DIN combo flange,  

PFA-coated fasteners 

P1500 PLASTIC 

   

 

 

 

 

 

 

 

 

               

 

                   

 

LEGEND  

P1500 /  X X X X X  / X  X  X /  X  X  / X X  X  / X X X X 

     

76 mm (3") Pump 
 
Maximum Flow Rate: 
878 lpm (232 gpm)

 

   

 

 

                                             

O-RING 

 

   

MODEL                      VALVE 

SEAT  SPECIALTY 

   

   

                  VALVE 

BALL 

CODE 

   

   

              DIAPHRAGMS 

   

   

          AIR 

VALVE 

 

   

   

        CENTER 

BLOCK 

 

   

   

      AIR 

CHAMBERS 

 

   

    

 

 

 

OUTER 

PISTON 

 

   

    

 

WETTED 

PATHS 

 

WILDEN PUMP DESIGNATION SYSTEM 

(if applicable) 

Summary of Contents for PSG Wilden PRO-FLO P1500

Page 1: ...WIL 11160 E 10 Where InnovationFlows EOM ENGINEERING OPERATION MAINTENANCE MANUAL P1500 Bolted Plastic Pump ...

Page 2: ... California LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are registered and unregistered trademarks of their respective owners Nothing contained in this document should be construed as granting any license or right to use any trademark without the prior written p...

Page 3: ...nce 8 P1500 Plastic Reduced Stroke PTFE Fitted 8 P1500 Plastic Full Stroke PTFE Fitted 8 Suction Lift Capability 9 SECTION 6 Suggested Installation Operation Maintenance and Troubleshooting 10 SECTION 7 Disassembly Reassembly 13 Pump Disassembly 13 Air Valve Disassembly 16 Reassembly Hints and Tips 18 Shaft Seal Installation 19 SECTION 8 Exploded View and Parts List 20 SECTION 9 Elastomer Options ...

Page 4: ...ity is not exceeded CAUTION Do not exceed 8 6 bar 125 psig air supply pressure CAUTION Do not exceed 82 C 180 F air inlet temperature for all models CAUTION The process fluid and cleaning fluids must be compatible chemically with all wetted pump components CAUTION Thoroughly flush pumps before installing them into process lines Clean and or sanitize FDA and USDA approved pumps before using them CA...

Page 5: ... POLYURETHANE EZ INSTALL CLEAR ZSS SANIFLEX EZ INSTALL HYTREL CREAM ZWS WIL FLEX EZ INSTALL SANTOPRENE THREE BLACK DOTS VALVE BALLS TF PTFE WHITE VALVE SEATS K PVDF VALVE SEATS MANIFOLD O RING TV PTFE ENCAP FKM SPECIALTY CODES 0100 Wil Gard II 110V 0102 Wil Gard II sensor wires Only 0103 Wil Gard II 220V 0206 PFA coated hardware Wil Gard II sensor wires ONLY 0480 Pump Cycle Monitor sensor wires 04...

Page 6: ...and manifold of the pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump discharge The movement of diaphragm A toward the center of the pump creates a vacuum within liquid chamber A Atmospheric pressure forces fluid into the inlet manifold of the pump The inlet valve ball i...

Page 7: ...IA N 150 5 9 FLANGES DIN mm ANSI inch P 160 DIA 6 0 DIA R 191 DIA 7 5 DIA S 18 DIA 0 8 DIA LW0404 REV A P1500 PVDF DIMENSIONS ITEM METRIC mm STANDARD inch A 914 36 0 B 160 6 3 C 694 27 3 D 1278 50 3 E 180 7 1 F 303 11 9 G 1183 46 6 H 694 27 3 J 584 23 0 K 681 26 8 L 335 13 2 M 15 DIA 0 6 DIA N 142 5 6 FLANGES DIN mm ANSI inch P 170 DIA 6 0 DIA R 190 DIA 7 5 DIA S 18 DIA 0 8 DIA A 914 36 0 DIMENSIO...

Page 8: ... 9 bar 100 psig air supply pressure on Polypropylene pumps Do not exceed 8 6 bar 125 psig air supply pressure on PVDF pumps P1500 PLASTIC FULL STROKE PTFE FITTED Ship Weights Polypropylene 138 kg 305 lb PVDF 161 kg 356 lb Air Inlet 19 mm 3 4 Inlet 51 mm 3 Outlet 51 mm 3 Suction Lift 5 5 m Dry 18 2 8 6 m Wet 28 4 Disp per Stroke1 5 8 L 1 52 gal Max Flow Rate 878 lpm 232 gpm Max Size Solids 12 7 mm ...

Page 9: ...000 above sea level This chart is meant to be a guide only There are many variables that can affect your pump s operating characteristics The number of intake and discharge elbows viscosity of pumping fluid elevation atmospheric pressure and pipe friction loss all affect the amount of suction lift your pump will attain SUCTION LIFT CAPABILITY ...

Page 10: ... minute and then multiplying that figure by the displacement per stroke Muffler Using the standard Wilden muffler sound levels are reduced below OSHA specifications You can use other mufflers to reduce sound levels farther but they usually reduce pump performance Elevation Selecting a site that is well within the pump s dynamic lift capability will assure that loss of prime issues will be eliminat...

Page 11: ...sed to regulate volume Pump discharge rate also can be controlled by throttling the pump discharge by partially closing a valve in the discharge line of the pump This action increases friction loss which reduces flow rate See Performance This is useful when the need exists to control the pump from a remote location When the pump discharge pressure equals or exceeds the air supply pressure the pump...

Page 12: ... be unable to shift Pump runs but little or no product flows 1 Check for pump cavitation Slow pump speed down to allow thick material to flow into liquid chambers 2 Verify that vacuum required to lift liquid is not greater than the vapor pressure of the material being pumped cavitation 3 Check for sticking ball check valves a If material being pumped is not compatible with pump elastomers swelling...

Page 13: ...fects of contact with your process fluid NOTE Your specific pump model may vary from the configuration shown however pump disassembly procedure will be the same NOTE The model used for these instructions incorporates PTFE diaphragms and balls Models with rubber diaphragms and balls are the same except where noted NOTE Replace worn parts with genuine Wilden parts for reliable performance Step 1 Ste...

Page 14: ...intake manifold from liquid chambers and center section to expose intake valve balls and seats Inspect the ball cage area of manifold for excessive wear or damage Repeat Steps 4 6 NOTE Two people or a jib crane is recommended to perform Step 8 Lift one side of the intake manifold then slide out the other side to remove the manifold from the mounting stand Normally inlet and discharge manifolds sho...

Page 15: ...om the shaft which remains connected to the opposite side diaphragm assembly Figure 10b Repeat disassembly instructions for the opposite liquid chamber Inspect diaphragm assembly and shaft for signs of wear or chemical attack Replace all worn parts with genuine Wilden parts for reliable performance Rubber TPE are not available To remove diaphragm assembly from shaft secure shaft with soft jaws a v...

Page 16: ...osen the air valve bolts utilizing a 3 8 hex head wrench Remove muffler plate and air valve bolts from air valve assembly exposing muffler gasket for inspection Replace if necessary Lift away air valve assembly and remove air valve gasket for inspection Replace if necessary Step 4 Step 5 Remove air valve end cap to expose air valve spool by simply lifting up on end cap once air valve bolts are rem...

Page 17: ...pilot spool from bushing and inspect spool and seals for nicks gouges or other signs of wear Replace pilot sleeve assembly or outer bushing O rings if necessary NOTE Seals should not be removed from pilot spool Seals are not sold separately The end of the pilot spool that has a center hole in it should not be fed into the bore first Check center section Glyd rings for signs of wear If necessary re...

Page 18: ...hite EP bearing grease or equivalent Clean the inside of the center section shaft bore to ensure no damage is done to new seals A small amount of NLGI grade 2 white EP bearing grease can be applied to the muffler and air valve gaskets to locate gaskets during assembly Make sure that the exhaust port on the muffler plate is centered between the two exhaust ports on the center section Stainless bolt...

Page 19: ... With the seal clamped in the pliers insert the seal into the busing bore and position the bottom of the seal into the correct groove When the bottom of the seal is seated in the groove release the clamp pressure on the pliers This will allow the seal to partially snap back to its original shape 6 After removing the pliers you will notice a slight bump in the seal shape Before the seal can be resi...

Page 20: ...WIL 11160 E 10 20 P1500 Bolted Plastic SECTION 8 P1500 PLASTIC LW0225 REV A ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS EXPLODED VIEW AND PARTS LIST ...

Page 21: ... 15 5185 20 15 5185 21 24 O Ring Tee Section 347 Ø4 225 x Ø 210 4 15 1300 60 25 Elbow Combo 4 15 5240 20 15 5240 21 26 O Ring Elbow 363 Ø6 475 X Ø 210 4 15 1370 60 27 Cage Ball 4 15 5350 20 15 5350 21 28 Screw HHC 3 4 10 x 8 3 8 24 15 6192 03 29 Washer Plain 3 4 Ø 812 x Ø1 750 x 095 48 15 6735 03 30 Nut Hex 3 4 10 24 15 6425 03 31 Chamber Liquid 2 15 5000 20 15 5000 21 32 Stand Pump 1 15 7650 03 V...

Page 22: ... 2 EZ INSTALL DIAPHRAGMS 2 FULL STROKE IPD DIAPHRAGMS 2 VALVE BALLS 4 Polyurethane 15 1022 50 Neoprene 15 1060 51 Geolast 15 1022 15 EPDM 15 1060 54 PTFE 15 1010 55 15 1040 55 15 1085 55 Non Food Grade SaniflexTM 15 1031 46 SaniflexTM 15 1065 56 15 1022 56 FDA Wil FlexTM 15 1065 57 15 1022 57 15 1085 57 Wil FlexTM 15 1022 58 15 1031 58 15 1085 58 LW0226 REV A ELASTOMER OPTIONS ...

Page 23: ...WIL 11160 E 10 23 P1500 Bolted Plastic NOTES NOTES ...

Page 24: ... USA P 1 909 422 1730 psgdover com Copyright 2021 PSG a Dover Company PSG reserves the right to modify the information and illustrations contained in this document without prior notice This is a non contractual document WIL 11160 E 10 Where InnovationFlows ...