Dover PSG Wilden PRO-FLO P1500 Engineering Operation & Maintenance Manual Download Page 2

 

WIL-11160-E-10  

P1500 Bolted Plastic 

Copyright 

Copyright 2018 PSG

®

, a Dover Company. All rights reserved. 

 
PSG reserves the right to modify the information and illustrations in this document without prior 
notice. The product described in this document is furnished under a license agreement or 
nondisclosure agreement. No part of this document may be reproduced, stored in a retrieval 
system, or transmitted in any form or any means electronic or mechanical, including 
photocopying and recording, without the written permission of PSG, a Dover Company, except 
as described by the terms of those agreements. 
 
This is a non-contractual document.  
 

Trademarks 

PSG and the PSG logo are registered trademarks of PSG. Wilden

®

 is a registered trademark of 

PSG California LLC. Pro-Flo

®

 SHIFT and Pro-Flo

®

 are registered trademarks of PSG California 

LLC. Wil-Flex

®

 is a trademark of PSG California LLC. Saniflex™ is a trademark of PSG 

California LLC. 
 
All trademarks, names, logos and service marks (collectively “trademarks”) in this document are 
registered and unregistered trademarks of their respective owners. Nothing contained in this 
document should be construed as granting any license or right to use any trademark without the 
prior written permission of the trademark owner. 
 

Warranty 

Each and every product manufactured by Wilden is built to meet the highest standards of 
quality. Every pump is functionally tested to ensure integrity of operation. Wilden warrants that 
pumps, accessories and parts manufactured or supplied by it to be free from defects in material 
and workmanship for a period of five (5) years from date of installation or six (6) years from date 
of manufacture, whichever comes first. 
 
For more information, and to register your Wilden pump for warranty, please visit 
https://www.psgdover.com/wilden/support/warranty-registration. 
 

Certifications 
 
 
 
 
 
 
 
 

 

Summary of Contents for PSG Wilden PRO-FLO P1500

Page 1: ...WIL 11160 E 10 Where InnovationFlows EOM ENGINEERING OPERATION MAINTENANCE MANUAL P1500 Bolted Plastic Pump ...

Page 2: ... California LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are registered and unregistered trademarks of their respective owners Nothing contained in this document should be construed as granting any license or right to use any trademark without the prior written p...

Page 3: ...nce 8 P1500 Plastic Reduced Stroke PTFE Fitted 8 P1500 Plastic Full Stroke PTFE Fitted 8 Suction Lift Capability 9 SECTION 6 Suggested Installation Operation Maintenance and Troubleshooting 10 SECTION 7 Disassembly Reassembly 13 Pump Disassembly 13 Air Valve Disassembly 16 Reassembly Hints and Tips 18 Shaft Seal Installation 19 SECTION 8 Exploded View and Parts List 20 SECTION 9 Elastomer Options ...

Page 4: ...ity is not exceeded CAUTION Do not exceed 8 6 bar 125 psig air supply pressure CAUTION Do not exceed 82 C 180 F air inlet temperature for all models CAUTION The process fluid and cleaning fluids must be compatible chemically with all wetted pump components CAUTION Thoroughly flush pumps before installing them into process lines Clean and or sanitize FDA and USDA approved pumps before using them CA...

Page 5: ... POLYURETHANE EZ INSTALL CLEAR ZSS SANIFLEX EZ INSTALL HYTREL CREAM ZWS WIL FLEX EZ INSTALL SANTOPRENE THREE BLACK DOTS VALVE BALLS TF PTFE WHITE VALVE SEATS K PVDF VALVE SEATS MANIFOLD O RING TV PTFE ENCAP FKM SPECIALTY CODES 0100 Wil Gard II 110V 0102 Wil Gard II sensor wires Only 0103 Wil Gard II 220V 0206 PFA coated hardware Wil Gard II sensor wires ONLY 0480 Pump Cycle Monitor sensor wires 04...

Page 6: ...and manifold of the pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump discharge The movement of diaphragm A toward the center of the pump creates a vacuum within liquid chamber A Atmospheric pressure forces fluid into the inlet manifold of the pump The inlet valve ball i...

Page 7: ...IA N 150 5 9 FLANGES DIN mm ANSI inch P 160 DIA 6 0 DIA R 191 DIA 7 5 DIA S 18 DIA 0 8 DIA LW0404 REV A P1500 PVDF DIMENSIONS ITEM METRIC mm STANDARD inch A 914 36 0 B 160 6 3 C 694 27 3 D 1278 50 3 E 180 7 1 F 303 11 9 G 1183 46 6 H 694 27 3 J 584 23 0 K 681 26 8 L 335 13 2 M 15 DIA 0 6 DIA N 142 5 6 FLANGES DIN mm ANSI inch P 170 DIA 6 0 DIA R 190 DIA 7 5 DIA S 18 DIA 0 8 DIA A 914 36 0 DIMENSIO...

Page 8: ... 9 bar 100 psig air supply pressure on Polypropylene pumps Do not exceed 8 6 bar 125 psig air supply pressure on PVDF pumps P1500 PLASTIC FULL STROKE PTFE FITTED Ship Weights Polypropylene 138 kg 305 lb PVDF 161 kg 356 lb Air Inlet 19 mm 3 4 Inlet 51 mm 3 Outlet 51 mm 3 Suction Lift 5 5 m Dry 18 2 8 6 m Wet 28 4 Disp per Stroke1 5 8 L 1 52 gal Max Flow Rate 878 lpm 232 gpm Max Size Solids 12 7 mm ...

Page 9: ...000 above sea level This chart is meant to be a guide only There are many variables that can affect your pump s operating characteristics The number of intake and discharge elbows viscosity of pumping fluid elevation atmospheric pressure and pipe friction loss all affect the amount of suction lift your pump will attain SUCTION LIFT CAPABILITY ...

Page 10: ... minute and then multiplying that figure by the displacement per stroke Muffler Using the standard Wilden muffler sound levels are reduced below OSHA specifications You can use other mufflers to reduce sound levels farther but they usually reduce pump performance Elevation Selecting a site that is well within the pump s dynamic lift capability will assure that loss of prime issues will be eliminat...

Page 11: ...sed to regulate volume Pump discharge rate also can be controlled by throttling the pump discharge by partially closing a valve in the discharge line of the pump This action increases friction loss which reduces flow rate See Performance This is useful when the need exists to control the pump from a remote location When the pump discharge pressure equals or exceeds the air supply pressure the pump...

Page 12: ... be unable to shift Pump runs but little or no product flows 1 Check for pump cavitation Slow pump speed down to allow thick material to flow into liquid chambers 2 Verify that vacuum required to lift liquid is not greater than the vapor pressure of the material being pumped cavitation 3 Check for sticking ball check valves a If material being pumped is not compatible with pump elastomers swelling...

Page 13: ...fects of contact with your process fluid NOTE Your specific pump model may vary from the configuration shown however pump disassembly procedure will be the same NOTE The model used for these instructions incorporates PTFE diaphragms and balls Models with rubber diaphragms and balls are the same except where noted NOTE Replace worn parts with genuine Wilden parts for reliable performance Step 1 Ste...

Page 14: ...intake manifold from liquid chambers and center section to expose intake valve balls and seats Inspect the ball cage area of manifold for excessive wear or damage Repeat Steps 4 6 NOTE Two people or a jib crane is recommended to perform Step 8 Lift one side of the intake manifold then slide out the other side to remove the manifold from the mounting stand Normally inlet and discharge manifolds sho...

Page 15: ...om the shaft which remains connected to the opposite side diaphragm assembly Figure 10b Repeat disassembly instructions for the opposite liquid chamber Inspect diaphragm assembly and shaft for signs of wear or chemical attack Replace all worn parts with genuine Wilden parts for reliable performance Rubber TPE are not available To remove diaphragm assembly from shaft secure shaft with soft jaws a v...

Page 16: ...osen the air valve bolts utilizing a 3 8 hex head wrench Remove muffler plate and air valve bolts from air valve assembly exposing muffler gasket for inspection Replace if necessary Lift away air valve assembly and remove air valve gasket for inspection Replace if necessary Step 4 Step 5 Remove air valve end cap to expose air valve spool by simply lifting up on end cap once air valve bolts are rem...

Page 17: ...pilot spool from bushing and inspect spool and seals for nicks gouges or other signs of wear Replace pilot sleeve assembly or outer bushing O rings if necessary NOTE Seals should not be removed from pilot spool Seals are not sold separately The end of the pilot spool that has a center hole in it should not be fed into the bore first Check center section Glyd rings for signs of wear If necessary re...

Page 18: ...hite EP bearing grease or equivalent Clean the inside of the center section shaft bore to ensure no damage is done to new seals A small amount of NLGI grade 2 white EP bearing grease can be applied to the muffler and air valve gaskets to locate gaskets during assembly Make sure that the exhaust port on the muffler plate is centered between the two exhaust ports on the center section Stainless bolt...

Page 19: ... With the seal clamped in the pliers insert the seal into the busing bore and position the bottom of the seal into the correct groove When the bottom of the seal is seated in the groove release the clamp pressure on the pliers This will allow the seal to partially snap back to its original shape 6 After removing the pliers you will notice a slight bump in the seal shape Before the seal can be resi...

Page 20: ...WIL 11160 E 10 20 P1500 Bolted Plastic SECTION 8 P1500 PLASTIC LW0225 REV A ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS EXPLODED VIEW AND PARTS LIST ...

Page 21: ... 15 5185 20 15 5185 21 24 O Ring Tee Section 347 Ø4 225 x Ø 210 4 15 1300 60 25 Elbow Combo 4 15 5240 20 15 5240 21 26 O Ring Elbow 363 Ø6 475 X Ø 210 4 15 1370 60 27 Cage Ball 4 15 5350 20 15 5350 21 28 Screw HHC 3 4 10 x 8 3 8 24 15 6192 03 29 Washer Plain 3 4 Ø 812 x Ø1 750 x 095 48 15 6735 03 30 Nut Hex 3 4 10 24 15 6425 03 31 Chamber Liquid 2 15 5000 20 15 5000 21 32 Stand Pump 1 15 7650 03 V...

Page 22: ... 2 EZ INSTALL DIAPHRAGMS 2 FULL STROKE IPD DIAPHRAGMS 2 VALVE BALLS 4 Polyurethane 15 1022 50 Neoprene 15 1060 51 Geolast 15 1022 15 EPDM 15 1060 54 PTFE 15 1010 55 15 1040 55 15 1085 55 Non Food Grade SaniflexTM 15 1031 46 SaniflexTM 15 1065 56 15 1022 56 FDA Wil FlexTM 15 1065 57 15 1022 57 15 1085 57 Wil FlexTM 15 1022 58 15 1031 58 15 1085 58 LW0226 REV A ELASTOMER OPTIONS ...

Page 23: ...WIL 11160 E 10 23 P1500 Bolted Plastic NOTES NOTES ...

Page 24: ... USA P 1 909 422 1730 psgdover com Copyright 2021 PSG a Dover Company PSG reserves the right to modify the information and illustrations contained in this document without prior notice This is a non contractual document WIL 11160 E 10 Where InnovationFlows ...

Reviews: