![Dover PSG ALL-FLO IOM A100 Series Installation Operation & Maintenance Data Download Page 8](http://html.mh-extra.com/html/dover/psg-all-flo-iom-a100-series/psg-all-flo-iom-a100-series_installation-operation-and-maintenance-data_2525008008.webp)
ALF-12050-E-02
All-Flo
8
PERFORMANCE CURVES
PERFORMANCE CURVE (1” RUBBER)*
Performance Specifications
Max. Flow:
48 gpm (182 lpm)
Max. Air Pressure:
120 psi (8.3 bar)
Max. Solids:
1/4” (6.4 mm)
Max. Suction Lift Dry:
17 ft-H
2
O (5.2 m-H
2
O)
Max. Suction Lift Wet:
30 ft-H
2
O (9.1 m-H
2
O)
Weight:
AL-18 lbs (8 kg) / SS-38 lbs (17 kg)
Air Inlet:
1/4” FNPT
Liquid Inlet:
1” FNPT or 1” FBSPT
Liquid Outlet:
1” FNPT or 1” FBSPT
Height:
12.4” (315 mm)
Width:
13.0” (330 mm)
Depth:
8.4” (213 mm)
Performance Specifications
Max. Flow:
48 gpm (182 lpm)
Max. Air Pressure:
120 psi (8.3 bar)
Max. Solids:
1/4” (6.4 mm)
Max. Suction Lift Dry:
17 ft-H
2
O (5.2 m-H
2
O)
Max. Suction Lift Wet:
30 ft-H
2
O (9.1 m-H
2
O)
Weight:
AL-18 lbs (8 kg) / SS-38 lbs (17 kg)
Air Inlet:
1/4” FNPT
Liquid Inlet:
1” FNPT or 1” FBSPT
Liquid Outlet:
1” FNPT or 1” FBSPT
Height:
12.4” (315 mm)
Width:
13.0” (330 mm)
Depth:
8.4” (213 mm)
Performance Specifications
Max. Flow:
45 gpm (170 lpm)
Max. Air Pressure:
120 psi (8.3 bar)
Max. Solids:
1/4” (6.4 mm)
Max. Suction Lift Dry:
17 ft-H
2
O (5.2 m-H
2
O)
Max. Suction Lift Wet:
30 ft-H
2
O (9.1 m-H
2
O)
Weight:
AL-18 lbs (8 kg) / SS-38 lbs (17 kg)
Air Inlet:
1/4” FNPT
Liquid Inlet:
1” FNPT or 1” FBSPT
Liquid Outlet:
1” FNPT or 1” FBSPT
Height:
12.4” (315 mm)
Width:
13.0” (330 mm)
Depth:
8.4” (213 mm)
5
SECTION
*Flow rates indicated on all three charts shown were determined by pumping water at flooded suction. For optimum life and performance, pumps should
be specified so that daily operation parameters will fall in the center of the pump performance curve.
PERFORMANCE CURVE (1” TPE)*
PERFORMANCE CURVE (1” PTFE)*
AIR CONSUMPTION (SCFM)
AIR CONSUMPTION (SCFM)
AIR CONSUMPTION (SCFM)