![Dover PSG ALL-FLO A100 Installation Operation & Maintenance Download Page 15](http://html1.mh-extra.com/html/dover/psg-all-flo-a100/psg-all-flo-a100_installation-operation-and-maintenance_2524998015.webp)
ALF-13150-E-01
All-Flo
15
STEP 7
Remove the “Air Valve Spool” from
the main “Air-Valve Assembly”.
Note: The longer piston is on the
plug side, insert larger chamfer
first.
STEP 8
Using the pick, remove the “Lip
Seal (Air Valve)” from the main
“Air-Valve Assembly”.
STEP 9
Using the pick, remove the
second “Lip Seal (Air Valve)” from
the main “Air-Valve Assembly”.
AIR VALVE ASSEMBLY
To assemble the air valve, reverse the order of disassembly. During
assembly, ensure that the open side of the lip-seals are both facing
each other inward. Install the shuttle plate with the smooth/shinny side
toward the shuttle car. Lubrication of the air valve assembly, with a non-
synthetic lubricant, is recommended. Magna-Lube or Magna-Plate are
recommended for assembly lubrication (see detailed parts list for
ordering information).
Note that if the lip-seals are installed incorrectly, they will be unable
to rotate. Insert the spool, larger chamfer side first, the spool’s longer
piston is to be on the plug side, ensure O-Ring is installed, and then the
air-valve end plug into position.