Installation, Operation & Maintenance Manual
16
Top-Transfer 2" Angle Valves A-720, A-721, A-721-B and A-724 Series
6.1.4
Take off the four (4) side flange bolts and lock washers (items 15A and 15B, respectively).
6.1.5
Carefully remove side outlet flange (item 7). It may be necessary to insert two (2) screwdrivers (180° degrees apart)
between the flange and the valve body to pry it out. Care to be taken so not to damage the mating surfaces
between the body and flange
Figure 6-4 Remove outlet flange
Figure 6-3 Remove flange bolts and washers