6
Remote Operation
6.1
Introduction
The following list of commands is what is supported by the 3205. These
commands must be issued to the Ethernet interface and will not be recongnized
on any other interface (i.e. RS-232 Console). All commands will return “OPC”
for operation complete after the command that was set sent is completed. In
the event the command returns a string, the requested string will be sent first,
then “OPC” will be sent separately. (i.e. send “ROUTE:PATH3 ?” then return
“OPC”).
6.2
Shortcuts
Keywords may be used in their short or verbose form. A list of commands and
their associated short form is listed below. None of the commands are case
sensitive. The user is free to send upper or lower case commands.
1. ROUT, ROUTE
2. SYST, SYSTEM
3. ERR, ERROR
6.3
ROUTE:PATHx y
Syntax
ROUTE:PATHx y
X = Input
Y = Output
Description
If output y is currently connected to different input, it will be disconnected from
its current input and connected to input x. This will be reflected on the graphical
touch screen display. By sending the command “ROUTE:PATH0 0” all paths
will be cleared.