Automatic Shutdown
The control will automatically turn OFF after being idle
for 20 minutes. To reactivate the control after a shut
down, move the ON/OFF switch to OFF, then back to
ON.
Smooth Stop
The control automatically allows the blade to coast to
a stop when the lever returns to center position. This
results in smoother operation, reduces the shock to the
hydraulic system, and increases hose and valve life.
STRAIGHT BLADE
JOYSTICK SOLENOID CONTROL
1. Turn the vehicle ignition switch to the "ON" or
"ACCESSORY" position.
2. Move control ON/OFF switch to the "ON" position.
The power indicator light glows red, indicating
the control is ON. The power indicator light glows
red whenever the control and the vehicle ignition
switch are both ON, the electrical connections to
the snowplow are completed and the power switch
on the light tower is in the "PLOWING" position.
If the power switch is in the "OFF" position, the
power indicator light will
fl
ash.
The ON/OFF switch operates as an emergency
stop if required.
Function Time-Outs
All control functions, except LOWER/FLOAT, time out
(stop) automatically after a period of time. This is to
limit the amount of electrical energy required from the
vehicle.
NOTE: If control function times out before desired
blade movement is complete, release the lever
to the center position, then move back into the
desired function.
OPERATING YOUR SNOWPLOW
WARNING
To prevent accidental movement of the blade,
always move the ON/OFF switch to OFF
whenever the snowplow is not in use. The
power indicator light will turn OFF.
CAUTION
DO NOT hold control lever in RAISE, ANGLE
LEFT, or ANGLE RIGHT position after blade
has reached desired position. To do so will
use excess current and overheat components.
L
R
RAISE
LOWER
ON / OFF
FLOAT
Float Light
(green)
ON/OFF
Switch
(emergency
stop)
Power Indicator