4
1. To change the time that the pump will start, unplug
the pump. Plug the pump back in at the desired
start time. You must wait a minimum of 30
seconds between unplugging and replugging.
2. Turn the switch to the "OFF" position and then
back to a run-time hour setting. The new run-time
will begin immediately and complete the run-time
cycle.
NOTE: In the event of a power failure, the timer will
act as though it has been unplugged, then replugged
when power is restored. In the auto mode, the pump
will start running its cycle when power is restored.
You will have to reset your “start-time" by unplugging
the pump, then replugging it at your desired “start-
time", or follow method two above.
MAINTENANCE
Make sure the pump is disconnected from the
electrical source before attempting any mainte-
nance work.
LUBRICATION
Periodically lubricate the O-Ring under the strainer
cover with a NON-PETROLEUM lubricant recom-
mended for A.B.S., Noryl and Acrylic plastics. Consult
your pool dealer for lubricant selections.
If you have any questions or require assistance,
contact your Doughboy pool dealer.
SERVICING SAFETY TIPS
1. ALWAYS TURN “OFF” the main power switch and the
Ground Fault Circuit Interrupter (GFCI) breaker switch so
power is completely off before servicing your unit.
2. ALWAYS BE SURE THE GROUND UNDER YOUR FEET
AND YOUR BODY IS DRY before you touch electrical
equipment. Failure to heed this warning may cause
personal injury due to severe electrical shock.
3. ALWAYS have a qualified electrician service your system
if electrical problems occur. This system uses UL listed
components and must be serviced by a qualified electri-
cian to insure that the electrical integrity is maintained.
Failure to do so may cause personal injury due to severe
electrical shock.
4. ALWAYS have a qualified electrician install a Ground
Fault Circuit Interrupter (GFCI) breaker at the electrical
service or supply panel. Follow GFCI manufacturer’s
operating instructions for testing. Failure to do so may
cause personal injury due to severe electrical shock.
CAUTION: To reduce the risk of electrical shock, connect
only to grounding type receptacles. A Ground Fault
Circuit Interrupter (GFCI) must be
provided in accor-
dance with local codes or ordinances.
CAUTION: To reduce the risk of electrical shock, use
only Original Equipment Manufactured (OEM) replace-
ment parts when servicing.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
6
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
Male Hose Adaptor
#8 x 1" Phillips Screw
Pump Volute
O-Ring Seal
Impeller Assy. w/seal, 1/3 HP
Impeller Assy. w/seal 1/2 HP
Impeller Assy. w/seal 3/4 HP & 1 HP
5/8" Pump Seal Set
Pump Seal Seat
5/8" Pump Seal
Pump Faceplate Assy.
Motor, 1/3 HP
Motor, 1/2 HP
Motor, 3/4 HP
Motor, 1 HP
Motor Clamp
1/4"-20 Hex Nut
1/4"-20 x 1" Bolt
Insulating Sleeve
1/3 HP Pump Assy.
1/2 HP Pump Assy.
3/4 & 1 HP Pump Assy.
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
348-1026
1150-1000
1150-1005
330-1023
1100-1118
1100-1115
303-1104
303-1120
1121-1776
1100-1117
1100-1116
1121-1777
340-1645
308-1106
308-1107
340-2341
340-2344
1100-1690
330-1285
343-1074
327-1036
365-1878
—
2
1
1
10
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Rubber Strip
Bottom Housing Assy.(-020 Models)
Bottom Housing Assy.(-026 Models)
#8 x 5/8" Screw
Cord Set Assy, 25'(-020 Models)
Cord Set Assy, 3' (-026 Models)
Strain Relief Bushing (-020 Models)
Strain Relief Bushing (-026 Models)
Top Housing/Decal Assembly.
Jumper Wire - Black
Jumper Wire - White
Timer Cover/Decal Assembly
Timer Body
Face Gasket
Body Gasket
Timer Mounting Bracket
Timer Knob
Timer Module Assembly
#8 x 1-1/2 Screw
Switch Hole Cover Plug
#8 Ext. Tooth Lockwasher (not shown)
Owner’s Guide
Warranty Card
ITEM P/N QTY DESCRIPTION
ITEM P/N QTY DESCRIPTION
340-1778
330-1016
305-1010
308-1005
1107-1143
1107-1142
1107-1141
1121-1577
308-1263
308-1264
1121-1582
300-1015
300-1016
300-1017
300-1043
385-1152
321-1004
324-1018
341-1123
1121-1583
1121-1584
1121-1585
PARTS LIST