SPECIFICATIONS: 

Connector: 

 

Phoenix Contact MSTB series 5 position two part terminal block 

 

 

 

Model: MTSB 2,5/5-ST-5,08 Order Number: 17 57 04 8 

 

Connector Pin Out: 

(V) 

Supply voltage “hot” 

 

 

 

(C) 

Supply common (internally tied to DMX512 common) 

 

 

 

(+) 

DMX512 data + 

 

 

 

(-) 

DMX512 data 

– 

 

 

 

(C) 

DMX512 common 

 
Input/Output Circuit: 

ESD protected EIA-485 transceiver (LT1785) 

Indicators: 

 

Ten green preset indicator LEDs 

 

 

 

One yellow Fade Time LED 

 

 

 

One red Signal / Record LED 

 
User Controls:   

Ten preset push buttons 

 

 

 

One recessed Fade Time push button 

 

 

 

One recessed Record push button 

 
Option Jumpers: 

For a single station installation, all jumpers should be installed (see figure 1, 
page 5). 

 

INSTALLED 

REMOVED 

JP1 

 

Recording Enabled 

Recording Disabled 

JP2 

Main Station 

Remote Station 

JP3 

Architectural Mode 

Portable Mode 

JP4 

Single Station Mode 

Multi Station Mode 

Power Input: 

 

9 to 15 volts AC or DC, 200mA per station 

 

 

 

(A 10 volt class 2 “doorbell” transformer is recommended for fixed installations) 

 
Color:   

 

Black anodized with silver engraved nomenclature 

Size: 

 

 

Faceplate: 4.5”h X 2.75”w X 0.2”d 

 

 

 

Faceplate rear insert: 4.05”h X 2.4”w X 0.1”d 

 

 

 

Electrical box minimum inside dimensions: 3.5”h X 2.1”w X 1.25”d 

 

 

 

Included back box: Raco 670RAC 

 

Summary of Contents for Preset 10 Architectural

Page 1: ...PRESET 10 ARCHITECTURAL OWNERS MANUAL Doug Fleenor Design 396 Corbett Canyon Road Arroyo Grande CA 93420 805 481 9599 Software Version 2 4 Manual Revision September 2019...

Page 2: ...tectural are power 2 wires and DMX512 3 wires Power for the Preset 10 can be supplied from a variety of sources including a 10V class 2 doorbell transformer The Preset 10 Architectural system can work...

Page 3: ...de Time push button One recessed Record push button Option Jumpers For a single station installation all jumpers should be installed see figure 1 page 5 INSTALLED REMOVED JP1 Recording Enabled Recordi...

Page 4: ...e Pin 3 TB1 3 Data 2 2 16 AWG Stranded Wires Black Power Supply Common TB1 4 Supply common Red Power TB1 5 Supply hot 3 120 Ohm Data Cable Belden 9829 or Equivalent Shield PRE10 Main TB1 1 PRE10 Remot...

Page 5: ...n architectural preset station When this jumper is removed the Preset 10 operates as a console backup portable station This jumper modifies the personality of the Preset 10 software JP4 When this jump...

Page 6: ...to set the individual dimmer levels recorded to a preset the Preset 10 must be connected to a DMX512 source When less than 512 dimmer levels are received a level of 0 will be stored for all channels a...

Page 7: ...D will now flash You will have ten seconds to set the crossfade time If you decide after depressing the TIME SETTING MODE button that you do not wish to make an edit simply wait ten seconds or depress...

Page 8: ...up in the time recorded to that preset If the Preset 10 was in autofollow playback at the time power was lost the Preset 10 will resume autofollow playback beginning with preset number 1 To bypass un...