SPECIFICATIONS:
Connector:
Phoenix Contact MSTB series 5 position two part terminal block
Model: MTSB 2,5/5-ST-5,08 Order Number: 17 57 04 8
Connector Pin Out:
(V)
Supply voltage “hot”
(C)
Supply common (internally tied to DMX512 common)
(+)
DMX512 data +
(-)
DMX512 data
–
(C)
DMX512 common
Input/Output Circuit:
ESD protected EIA-485 transceiver (LT1785)
Indicators:
Ten green preset indicator LEDs
One yellow Fade Time LED
One red Signal / Record LED
User Controls:
Ten preset push buttons
One recessed Fade Time push button
One recessed Record push button
Option Jumpers:
For a single station installation, all jumpers should be installed (see figure 1,
page 5).
INSTALLED
REMOVED
JP1
Recording Enabled
Recording Disabled
JP2
Main Station
Remote Station
JP3
Architectural Mode
Portable Mode
JP4
Single Station Mode
Multi Station Mode
Power Input:
9 to 15 volts AC or DC, 200mA per station
(A 10 volt class 2 “doorbell” transformer is recommended for fixed installations)
Color:
Black anodized with silver engraved nomenclature
Size:
Faceplate: 4.5”h X 2.75”w X 0.2”d
Faceplate rear insert: 4.05”h X 2.4”w X 0.1”d
Electrical box minimum inside dimensions: 3.5”h X 2.1”w X 1.25”d
Included back box: Raco 670RAC