REAR INTERFACE  

The PRE10ETHER-A has a set of rear mounted controls that are accessed during initial 
commissioning of the wall station. The rear interface changes network settings, lockouts 
and button behavior. Once setup is complete, this interface remains facing into the two 
gang wall box and is not accessed by users changing presets on the front interface.  

The rear interface has a monochrome graphical Liquid Crystal Display (LCD), and a 
rotary encoder with a button. The LCD displays the configuration pages which are 
edited by turning the encoder, and pressing the button. The configuration page changes 
when the page change symbol is highlighted [< >] and the encoder wheel is turned. 
Depressing the encoder shaft acts as a button to toggle between the editable fields on 
the screen. A highlight appears in the background of the editable field, at which point 
the wheel changes the highlighted value. In addition to the LCD and encoder based 
configurations, three jumpers select settings that are not accessed in the LCD menus. 

 

 

Summary of Contents for PRE10ETHER-A

Page 1: ...of 10 Preset 10 Ethernet Interface Configuration Owner s Manual model PRE10ETHER A Doug Fleenor Design Inc 396 Corbett Canyon Road Arroyo Grande CA 93420 805 481 9599 Voice and FAX Manual Revision Jun...

Page 2: ...DC power input Station configuration takes place on a rear facing user interface Multiple stations may operate on the same universes and stations operating on different universes may operate on the sa...

Page 3: ...evice A more complex system may have PRE10ETHER A stations at multiple locations in a building Data transport between each sACN capable device takes place using standard Ethernet hardware that support...

Page 4: ...l Liquid Crystal Display LCD and a rotary encoder with a button The LCD displays the configuration pages which are edited by turning the encoder and pressing the button The configuration page changes...

Page 5: ...universes 6 7 8 and 9 Since each universe contains 512 slots this gives the PRE10ETHER A control of up to 2 048 slots PRIORITY sACN uses a priority value to instruct receiving devices on which stream...

Page 6: ...t of the active presets DATA Displays the value of the first slot of the first universe being received by the PRE10ETHER A The Data page does not display data transmitted by the PRE10ETHER A This is p...

Page 7: ...ing the front interface a user can select an active preset or determine a lockout condition The recessed RECORD and FADE TIME buttons require a small blunt object such as a paper clip PLAYBACK OF PRES...

Page 8: ...when a preset is turned on and when a preset is turned off In both RADIO and POPO mode whenever a fade takes place the yellow FADE TIME INDICATOR led will illuminate Note If one or more static preset...

Page 9: ...illuminate 3 Using a small blunt object e g paper clip momentarily depress the TIME SETTING MODE recessed button located on the bottom most left of the PRE10ETHER A The green LED indicator of the pre...

Page 10: ...g systems will enter their standby mode This feature can be disabled by recording any non zero level on any of the 2 048 channels into preset number 10 OFF Limited Manufacturer s Warranty Products man...

Reviews: