background image

Safety instructions

In order to protect the exposed connection cable when there is a risk of animal damage, it should 

be equipped with a Marten protection (mounting accessories) are provided. Luminaires / power 

supplies with defective cables must not be operated any further.

High ambient temperatures shorten the service life of the LEDs. To get a long lifetime of the LED, 

good heat dissipation must be ensured. Therefore, do not expose the LED spotlight to ambient tem-

peratures> 50 ° C during operation. Do not cover the LED spotlight, ensure that air can circulate 

freely.

Installation

Unpack the entire scope of delivery and check the contents for completeness and Integrity. Dispose 

of packaging material that is no longer required in accordance with the applicable regulations.

First attach the mounting bracket of the light to the ground spike with an M6 screw and a locking 

ring. The mounting bracket can also be attached directly to suitable surfaces without a ground 

spike.

Then the LED spotlight can be screwed into the bracket, the plastic washers are placed between 

the lamp and bracket, then the bracket is screwed on the left and right with two M6 screws and a 

locking ring. Align the lamp accordingly before tightening the screws.

Plug the connection cable of the spot into the corresponding socket of the power supply unit. If 

further extension sets are connected, use the corresponding cable distributor and, if necessary, the 

extension cable available as a special accessory. Make sure that the union nuts of the connectors 

are firmly tightened, this is the only way to guarantee protection against moisture. The connector 

system is reverse polarity protected. We recommend burying the connection cables to protect them 

from being bitten by animals or laying them in a conduit. The power supply unit should be placed 

in a location that is as protected from the weather as possible. Avoid constant moisture and direct 

sunlight. Make sure that the power supply unit cannot be flooded, even in heavy rain. The power 

supply unit must not be buried. If necessary, use a housing to protect the power supply unit from 

the elements.

Maintenance, care

Clean the LED spotlight from time to time with a damp cloth. Do not cover the spots, remove any 

leaves covering the LED spot and ensure that heat can dissipate freely from the housing. 

dot-spot 

mini LED garden spotlights 3W

 are built without potting, so they can be dismantled and repaired. 

This is also an important contribution to environmental protection. Even after the warranty period 

has expired, the LED spotlight can be repaired in the event of a fault or damage dot-spot offers 

attractive flat-rate repair fees. 

Disposal

 

When the end of use is reached, dispose of the spotlight and all accessories in accordance with 

the applicable environmental regulations. Electrical waste must not be disposed of together with 

household waste. The 

dot-spot mini LED garden spotlights 3W

 can be dismantled into individual 

parts after use and thus optimally recycled.

10

en

Summary of Contents for 25104

Page 1: ...dot spot Gartenstrahler Set mini de Bedienungsanleitung en Operator s Manual...

Page 2: ...ler Set mini 3W installieren oder verwenden Bewahren Sie die Anleitung gut auf Falls Sie den Strahler an Dritte weitergeben geben Sie auch die Gebrauchsanleitung mit Die Nichtbeachtung dieser Anleitun...

Page 3: ...iedene Bodeneinbausch chte lieferbar Produktbeschreibung EG Konformit tserkl rung Hiermit erkl rt dot spot Gmbh Co KG dass die dot spot mini LED Gartenstrahler Sets der Richt linie 2004 108 EG entspri...

Page 4: ...nen Schlie en Sie den LED Strahler nur an Netzteile an deren Ausgangsspannung 24 V DC nicht berschreitet berpr fen Sie ob die Netzspannung mit der des Netzteils bereinstimmt Falsche Spannungen k nnen...

Page 5: ...en Stecken Sie das Anschlusskabel des LED Strahlers in die entsprechende Buchse des Netzteils Werden weitere Erg nzungs Sets angeschlossen verwenden Sie die entsprechenden Kabelvertei ler und ggf das...

Page 6: ...e Gew hrleistung umfasst keine Sch den die durch normale Abnutzung oder mechanische Zer st rung durch Krafteinwirkung von au en entstanden sind Die Gew hrleistung umfasst den Ersatz der defekten Teile...

Page 7: ...spot mini LED garden spotlight Set 3W Keep this manual in a safe place In case you forward the spot towards third persons also give them the operating manual Failure to follow these instructions may c...

Page 8: ...afe installation of the power supply unit Product description EC declaration of conformity Hereby declares dot spot GmbH Co KG that the dot spot mini LED garden spotlight Set corre sponds to Directive...

Page 9: ...y connect the LED spotlight to power supplies whose out put voltage does not exceed 24 V DC Check whether the mains voltage matches that of the power supply unit Incorrect voltages can destroy the LED...

Page 10: ...ributor and if necessary the extension cable available as a special accessory Make sure that the union nuts of the connectors are firmly tightened this is the only way to guarantee protection against...

Page 11: ...resulting from normal wear or mechanical destructions by outside forces The warranty covers replacement of defective parts There shall be no entitlement to the com pensation for consequential damages...

Page 12: ...Vertrieb Industriestra e 1A 90592 Schwarzenbruck Deutschland Telefon 49 0 9128 72 22 17 0 Telefax 49 0 9128 72 22 17 9 Email service dot spot de Web www dot spot de Gebrauchsanleitung dot spot Gartens...