4-8
SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005
1. Use a Phillips screwdriver to remove the screw and cylindrical standoff from one of
the two provided cord locks.
Set them aside for reassembly later.
2. Slide the cord lock over the AC power connector.
3. Hold the cylindrical standoff between the two screw holes on the flanges of the cord
lock.
4. Insert the screw into the first screw hole, through the standoff, and then into the
threaded screw hole on the other flange.
5. Tighten the screw with a screwdriver
until the flanges bottom out on the cylindrical
standoff.
6. Push the power cord into the power supply receptacle until it is firmly seated.
7. Push the green ejector handle forward until it is seated against the power supply.
8. Turn the thumbscrew of the green ejector handle clockwise until it is finger-tight to
secure the handle and the cord lock.
Note –
To ensure that a thumbscrew is finger-tight, tighten it with a screwdriver and
then loosen the thumbscrew counterclockwise a quarter turn.
9. Repeat Step 1 through Step 8 for the second cord lock and second power cable.