![Dorner 2100 Series Set-Up & Operating Manual Download Page 8](http://html.mh-extra.com/html/dorner/2100-series/2100-series_set-up-and-operating-manual_2523111008.webp)
2100, 4100, 6100 Series Top Mount Drive Package for Standard Load Parallel Shaft 60 Hz Gearmotors SOMM
851-255 Rev. D
8
Dorner Mfg. Corp.
2
.
For three phase motor:
a
. Loosen terminal box screws (X of Figure 11) and
remove cover (Y).
Figure 11
Y
X
b
. Record incoming wire colors connecting to red,
black and blue leads. Loosen wire nuts and remove
incoming wires.
c
. Loosen cord grip and remove cord.
3
.
For DC variable speed motor, unplug motor cord at
disconnect (Z of Figure 12).
Figure 12
Z
4
.
Remove four (4) screws (L of Figure 8) and remove
cover (K).
5
.
Loosen tensioner (V of Figure 9).
6
.
Loosen drive pulley set screws (AA of Figure 13).
Remove drive pulley (J) and timing belt (P).
Figure 13
AA
J
P
7
.
Remove four (4) gear motor mounting screws (Q of
Figure 14). Remove gearmotor.
Figure 14
Q
Q
8
.
Remove four (4) adapter plate screws (AB of Figure
15). Remove adapter plate.
Figure 15
AB
AB
9
.
Install new gearmotor to adapter plate and mounting
bracket. Tighten screws (Q of Figure 14) to 103 in-lb
(12 Nm).
NOTE:
Drive pulley (J of Figure 13) is removed.
Wrap timing belt around drive pulley and complete
step 10.
10
.
Complete steps 5 through 8 of “Installation” section
beginning on page 5.
11
.
Replace wiring:
D
For a single phase motor, reverse step 1 on page 7.
D
For a three phase motor, reverse step 2, on this page.
D
For a DC variable speed motor, reverse step 3 on this
page.
Preventive Maintenance and Adjustment
Preventive Maintenance and Adjustment