Dornbracht
Sensory Sky
ATT
Planning
guide
Page 24/38
Plumbing
flow at 3 bar flow pressure (max.)
- Head spray
11,7 l/min.
- Body spray
12,2 l/min.
- Rain curtain
12,2 l/min.
- Cold-water mist spray
0,7 l/min.
- Sprays combined
35,7 l/min.
- Hand shower
8,0 l/min.
flow choreographies
- ReADjuST(4:50 min.):
max. 90 l
- ReLeASe (5:00 min.):
max. 104 l
- RejOICe (4:35 min.):
max. 104 l
flow pressure
Measuring point: concealed rough parts for eVALVe
(hand shower set)
Minimum flow pressure
2,5 bar
Maximum flow pressure
4,0 bar
Maximum difference in flow
pressure between hot and cold water
1,0 bar
Recommended flow pressure
3,0 bar
Permissible operating temperatures
Measuring point: concealed rough parts for eVALVe
(hand shower set)
Hot-water temperature range
50-60 °C
Thermal disinfection (3-10 min.)
75 °C
Cold-water temperature range
5-20 °C
Anti-scald factory setting
43 °C
Rough-in depth rain panel, control elements, concealed
rough parts for eVALVe see page 18
Electrical
ceiling installation enclosure for rain panel
electricity supply (input voltage)
in the sub-distribution board
100-240 V AC
electricity supply (input voltage)
in the ceiling installation enclosure for rain panel
12 V DC
Input frequency
50-60 Hz
Maximum power consumption
180 W
Output voltage
12 V DC
Output current
3x 5 A
Power consumption (when not in use)
< 5 W
Power consumption (in use)
160 W
System of protection
IP 54
equipotential bonding
4 mm²
Installation depth min. 185 mm
control elements
Display switch
+ rotary knob
Input voltage
12 V DC
System of protection
IP X4
Hole diameter concealed box
56 mm
Installation depth min. 139 mm
concealed rough parts for eValVe
(hand shower set)
Input voltage
12 V DC
System of protection
IP 66
equipotential bonding
4 mm²
Installation depth
min. 139 mm
max. 164 mm
fragrance module
Input voltage
230 V AC
Input frequency
50-60 Hz
Maximum power consumption
30,6 W
(for 3 modules)
Technical data
Positioning
recommendations
Components
Zones of protection
Pre-wall installation