background image

3

TS 93 

B

 EN 2-5 / 5-7

mit Brandschutzplatte

with fire protection plate

2021-06

dormakaba Montageanleitung

Mounting instructions

Information about this document

WN 060290 45532

Information about this document

1.1  Contents and purpose

This manual enables the safe mounting of door closer 

TS 93 B

 with fire protection plate. Before commencing 

any work, personnel must have carefully read through 
and understood this manual. Complying with all 
safety instructions and action steps provided in this 
manual is the basic prerequisite for safe working.

 

1.2  Target group 

The fire protection plate and door closer must be 
mounted only by technically qualified personnel.

1.3  Other applicable documents

•  The supplied drilling template for the fire protection 

plate 060286 45532

1.4  Document storage

This manual and the applicable documents must be 
kept during the service life of the product and must 
be passed on with the product.

1.5  Symbols used

1.5.1  Hazard categories

CAUTION

This signal word indicates a possible 
hazardous situation that may result in minor 
or slight injury if not avoided.

1.6  Mounting information

•  The Figures in this manual show mounting for 

TS 93 B  EN 

2-5

. Assembly of the TS 93 B EN 5-7 

corresponds to the sequence shown.

•  The Figures in this manual show the mounting for 

DIN-L. For DIN-R, the instructions must be mirror-
inverted.

Safety

2.1  Intended use

•  The fire protection plate is only suitable for TS 93 B 

EN 2-5/EN 5-7.

•  The door closer is intended solely for the controlled 

closing of single-action doors.

•  Adhere to the specified torques.

2.2  Reasonably foreseeable misuse

•  Do not unscrew the valves.
•  Do not open the door closer.

2.3  Basic warnings

CAUTION

Risk of injury due to improper mounting!

Incorrect assembly can cause injury. 
•  Use dowels and screws that are suitable 

for the existing structure. 

•  See how the valves are closed in Figure 7.

EN

Summary of Contents for TS 93 B EN 2-5

Page 1: ...erzugeben 1 5 Verwendete Symbole 1 5 1 Gefahrenkategorien VORSICHT Dieses Signalwort weist auf eine möglicherweise gefährliche Situation hin die zu geringfügigen oder leichten Verletzungen führen kann wenn sie nicht gemieden wird 1 6 Montagehinweis Die Abbildungen in dieser Anleitung zeigen die Montage des TS 93 B EN 2 5 Die Montage des TS 93 B EN 5 7 entspricht der abgebildeten Reihenfolge Die Ab...

Page 2: ...3 2 Zusätzlich benötigte Artikel Abb 3 Gleitschiene Art Nr 640100xx 3 3 Technische Daten Schließkraft EN 2 5 Temperaturbereich 60 C bis 15 C Türbreite max 1 250 mm Schließkraft EN 5 7 Temperaturbereich 60 C bis 15 C Türbreite max 1 600 mm Türöffnungswinkel Bandseite max 180 Bandgegenseite max 120 bis 145 4 Demontage und Entsorgung Die Demontage erfolgt in umgekehrter Reihenfolge der Montageanleitu...

Page 3: ...must be kept during the service life of the product and must be passed on with the product 1 5 Symbols used 1 5 1 Hazard categories CAUTION This signal word indicates a possible hazardous situation that may result in minor or slight injury if not avoided 1 6 Mounting information The Figures in this manual show mounting for TS 93 B EN 2 5 Assembly of the TS 93 B EN 5 7 corresponds to the sequence s...

Page 4: ...g of screws 3 2 Other required articles Fig 3 Slide rail Art No 640100xx 3 3 Technical data Closing force EN 2 5 Temperature range 60 c to 15 C Door width Max 1250 mm Closing force EN 5 7 Temperature range 60 c to 15 C Door width Max 1600 mm Door opening angle Hinge side Max 180 Opposite side to the hinge Max 120 to 145 4 Disassembly and disposal Dismantling is carried out in reverse order to the ...

Page 5: ...ection plate 2021 06 dormakaba Montageanleitung Mounting instructions Mögliche Einbaulagen Possible mounting positions WN 060290 45532 5 Mögliche Einbaulagen Possible mounting positions 5 1 Türblattmontage Door panel mounting 5 2 Sturzmontage Lintel mounting ...

Page 6: ...ndschutzplatte with fire protection plate 2021 06 dormakaba Montageanleitung Mounting instructions Türblattmontage Door panel mounting WN 060290 45532 6 Türblattmontage Door panel mounting 2 1 3 4 2 5 0 5 Nm 3 1 5 9 12 Nm 5 6 7 8 ...

Page 7: ...ction plate 2021 06 dormakaba Montageanleitung Mounting instructions Türblattmontage Door panel mounting WN 060290 45532 5 8 10 Nm 9 10 70 0 11 X1 X2 EN 2 5 850 mm 1 250 mm EN 5 7 1 250 mm 1 600 mm EN3 X1 5 X2 1 12 13 7 0 180 120 SV DC 70 70 ÖD BC 14 2 4 3 15 ...

Page 8: ...ndschutzplatte with fire protection plate 2021 06 dormakaba Montageanleitung Mounting instructions Sturzmontage Lintel mounting WN 060290 45532 17 2 5 2 5 17 17 7 Sturzmontage Lintel mounting 2 1 3 4 2 5 0 5 Nm 3 5 9 12 Nm 5 6 16 ...

Page 9: ...ire protection plate 2021 06 dormakaba Montageanleitung Mounting instructions Sturzmontage Lintel mounting WN 060290 45532 1 7 8 5 8 10 Nm 9 10 70 0 11 X1 X2 EN 2 5 850 mm 1 250 mm EN 5 7 1 250 mm 1 600 mm EN3 X1 5 X2 1 13 7 0 120 SV DC 70 2 4 12 145 ...

Page 10: ... 93 B EN 2 5 5 7 mit Brandschutzplatte with fire protection plate 2021 06 dormakaba Montageanleitung Mounting instructions Sturzmontage Lintel mounting WN 060290 45532 70 ÖD BC 14 16 3 17 2 5 2 5 17 17 15 18 ...

Page 11: ...11 TS 93 B EN 2 5 5 7 mit Brandschutzplatte with fire protection plate 2021 06 dormakaba Montageanleitung Mounting instructions Sturzmontage Lintel mounting WN 060290 45532 ...

Page 12: ...dormakaba Deutschland GmbH DORMA Platz 1 58256 Ennepetal Deutschland T 49 2333 793 0 F 49 2333 793 4950 www dormakaba com ...

Reviews: