4 Mounting
4.1 Safety during mounting
WARNING
Danger to life from crowding in front of a
jammed door.
If the door leaf is deformed by more than
5 mm, the door may not always open
reliably!
• SVI/SVA locks should only be installed in
doors with a maximum deformation of
5 mm!
• In case of more severe deformation, verify
that the door opens reliably with the
fitting!
WARNING
Danger to life due to incorrect mounting on
fire and smoke protection doors.
Mounting on fire and smoke protection
doors is only permitted if the usability
certificates for these doors provide for the
mounting.
• Observe the requirements in the usability
certificates.
TIPS AND RECOMMENDATIONS
• The mounting is shown on a DIN-left door.
For a DIN-right door, the procedure must
be mirror-inverted.
• The mounting is shown with a long plate.
For other door fittings, other mounting
points may have to be used.
4.2 Requirements for mounting
• The door corresponds to the specifications in Fig. 18
and is deformed by a maximum of 5 mm.
• For mounting along escape routes:
The door opens in the escape direction. If the door
opens in the opposite direction to the escape
direction, a building authority permit must be
obtained.
• There are recesses and pre-drilled holes in the (fixed
leaf) door leaf (see chapter 4.3).
• For all locks except SVI 5000:
The door leaf is equipped with the connection cable
SVP-A 1100/2100.
Fig. 18
max. 1300
max. 1300
2.5-5
max
. 2500
2-
7
2-
7
1050
FFL
max. 250 kg
max. 250 kg
Requirements for the door
11
SVI Lock
2019-12
dormakaba Mounting instructions
Mounting
WN 059741 45532