                                         Electrical Installation Instructions

1.  The reader comes with 16 feet of non-shielded cable. The type of cable used to extend the distance will affect the maximum 

distance the reader can be extended.

  Switch 2 control board to reader – Maximum cable run = 300 feet (100 m)

2.  The micro Reader will be sent out with a RJ45 connector on it. This can be cut off and the cable stripped back ready for wiring.

3.  Mount Switch 2 control board into power supply cabinet with stand-offs supplied.

4.  Connect reader to control board as shown in Fig. 5. If additional reader is required for in/out operation, wire the reader in 

parallel.

5.  Reader operates on 12VDC only. Connect reader to power transformer and electric lock as shown in Fig. 6 or Fig. 7.

Note: 

Unit requires a filtered and regulated power source for proper operation. See our line of power supplies and transformers for 

options to use.

Fig. 3

Fig. 4

Micro Reader surface mounted onto wall using back plate.  

The plastic end cap is placed over the exposed end of the reader.

Micro Reader surface mounted onto a hollow wall using the back 

plate. The plastic end cap is placed over the base plate.

Fig. 5

Proximity Micro Reader Wiring Diagram

Proximity Slimline Reader Wiring Diagram

Note:

 All installations must conform to local fire, National Building, and Life Safety Codes.

Summary of Contents for READ-PROX RCI 9321

Page 1: ...t wall with LED s at bottom mark position of three mounting holes 6 Drill the three mounting holes as appropriate for the type of fasteners being used 7 Install level the reader and secure with three mounting screws 8 Install removable cover by engaging top tab and pivoting cover down over reader Cover should snap in place when installed properly 9 Cover is secured with single screw provided on lo...

Page 2: ...er to control board as shown in Fig 5 If additional reader is required for in out operation wire the reader in parallel 5 Reader operates on 12VDC only Connect reader to power transformer and electric lock as shown in Fig 6 or Fig 7 Note Unit requires a filtered and regulated power source for proper operation See our line of power supplies and transformers for options to use Fig 3 Fig 4 Micro Read...

Page 3: ...Canada Inc www dormakaba us Phone 1 800 265 6630 Fax 1 800 482 9795 E mail sales_RCI dormakaba com Fig 7 Proximity MicroReader Red Fig 6 Proximity Micro Reader or or Proximity Slimline Reader Proximity Slimline Reader ...

Page 4: ...ard 1 Take Silent Operation function card from Wallet 2 Present card to reader s Reader will beep 3 Switch 2 control unit is now in silent operation mode 4 Present card again to disable silent operation mode Reader will beep To Enroll another Card Pack 1 Additional Card Pack s may be added as needed 2 To enroll an additional Card Pack first present the Enrolment Card from any currently enrolled Ca...

Reviews: