dormakaba MUTO Premium XL150/80/120 / MUTO Comfort L80
Fixed Panel Installation Instructions
MUTO Premium/Comfort Fixed Panel
05-2018
936020
9
U-channel
Sidelite glass
2.5.1 Install gaskets as shown. Trim to correct length.
2.5.1 Secure u-channel to floor using appropriate
fasteners.
NOTE: Ensure U-channel is plumb and the back of the
u-channel profile aligns with back of sidelite profile.
NOTE: Gaskets are pre-installed.
U-channel
2.5
Installing U-channel for sidelite
Fig. 3 U-channel
2.6
Installing sidelite glass
2.6.1
Place setting blocks into u-channel.
2.6.2
Spray inside of u-channel with glass cleaner.
2.6.3
Lift glass up and into sidelite profile.
2.6.4
Lower glass down into u-channel.
2.6.5
Ensure there is 1/8" [3] gap between wall and
edge of sidelite glass.
NOTE: If using tempered laminated glass, gently press
glass against u-channel gasket, and dispense silicone
along full length of non-gasket side of u-channel.
NOTE: If using multiple sidelite panels, ensure there is
an adequate gap between each panel of glass.
U-channel
setting
blocks
Sidelite
profile
Sidelite
glass
U-channel
Lift up
into
sidelite
profile
Lower
down
into
u-channel
Sidelite
glass
1/8" [3]
gap
Sidelite
glass
Wall
Fig. 4 Sidelite glass
Orient gasket(s) as shown.
U-channel
gasket