59
ED250
01-2018
DL4614-080
dormakaba ED250 IG Service Manual
Chapter 21
6
7
10
8
9
3
3
4
8
12
1
Fig. 21.3.4 Spindle lateral adjustment
Fig. 21.3.3 Spindle side adjustment
1
Spindle
2
5/16" x 3/8" flange
head cap screw
3
Slide mounting
plate
4
1/4" x 3/4" cap
screw
8
Main extrusion,
operator mounting
12
Cement case
6
5/16" x 1" cap screw
7
Block, operator
mounting
8
Operator mounting
main extrusion
9
Angle iron with
threaded hole for (6)
10
Pad, operator
mounting
12
Cement case
21.3.2 Operator mounting main extrusion
side position against cement case.
1. Two side mounting plates (Fig. 21.3.3,
item 3) are used as spacers holding
extrusion against opposite cement case
wall.
21.3.3 Main extrusion side position
adjustment.
1. 1/4" x 3/4" cap screw (Fig. 21.3.3,
item 4) is used to move extrusion against
opposite cement case wall (factory
adjustment).
21.3.4 Main extrusion lateral position.
1. 5/16" x 1" cap screw and operator
mounting block and pad
(Fig. 21.3.4, item 6,7 and 10).
2. Cap screw is adjusted against block and
pad to hold position of main extrusion
against end of cement case (factory
adjustment).