22
ED100/ED250
02-2018
DL4614-050
dormakaba ED100/ED250 Service Manual
Chapter 13
13 Perform learning cycle
13.1 Perform learning cycle
CAUTION
Learning cycle must be performed while
motor is cold!
CAUTION
Door must not be manually moved or held in
position during the learning cycle!
CAUTION
Verify that the following parameters have
been set (Para 15.1.8):
• AS
, Installation type
• rd
, Reveal depth
• Tb
, Door width
TIPS AND RECOMMENDATIONS
During learning cycle:
• Safety sensors and activators, are switched off to
insure learning cycle sequence is not interrupted.
• Operator functions are deactivated.
Step 3
Press
Press and hold down button until display
changes.
• Door performs several movements
and display shows a sequence of
symbols.
• Movements of door must not be
interrupted!
Display indicates door is at 70° position
and is waiting for door opening angle to
be set.
Step 4
• Manually move door to desired
opening angle.
Maximum door angle is 110°.
Step 5
Press
Momentarily press down button to
continue learning cycle.
• Door performs several movements
and display shows a sequence of
symbols.
• Movements of door must not be
interrupted!
Operator spring tension too low.
• Display with small rotating "o" and
an "F" during learn cycle indicates
spring tension is too low.
• Door will close.
1. Increase spring tension (Chapter 11).
2. Restart learning cycle (Step 3).
Door completes learning cycle.
• Display with two horizontal bars
indicate operator is ready for
operation.
Step 6
Press
Momentarily press down button to cycle
door.
Step 7
Following automatic learning cycle,
actual forces on door, and door
opening and closing times must be
measured and changed if necessary
to insure compliance with
ANSI/BHMA standards, reference
Chapter 14.
Step 9
Set program switch to Auto.
WARNING
No personnel or objects must be in range of
door motion during learn cycle!
Step 2
Set program switch to CLOSE position.
Rotating "o" and a "0" indicates
operator learning cycle is required.
Step 1
Secure motion range of door.