Construction and function
Technical Manual
20
04046493 - 11/2018
dormakaba Remote Reader 91 15 -
U300
4.4
System connection
User n
Master
User 1
91 15
State
IN1
IN2
OUT
G
ND
AC-
AC+
B
A
C
G
ND
IN1
IN2
2
1
Push
Click
DIN-
Rail
AS
A+
OUT
Output
Ant.
Function
0 - F
123456
ON
OFF
RS-485
Input
Programmer
Supply
10-34VDC
12-27VAC
34VDC
Class II
Relay Output
27VAC
max 5VDC
1
2
3
ENTER
2
1
ABC
3
DEF
5
JKL
4
GHI
6
MNO
8
0
TUV
7
PQRS
9
WXYZ
The Remote reader (2) can be programmed in the following ways:
•
With programmer 1364 (1) (authorisation list or CardLink)
•
With master and user media
It is not possible to program time functions and perform traceback read-outs (event
memory) with this type of programming.
Remote reader functions
•
Authorisation check
•
Relay control (e.g. for electric strikes)
•
chapter provides information on additional functions
Registration unit functions
•
Reading the media presented (RFID)
•
Optical and acoustic signalling
4.5
System requirements
Standalone mode
System software
KEM
KEM 3.0 and above
Kaba exos
Kaba exos 2.3 and above
4.6
Behaviour when several media are present in the field (anti-
collision)
The device (Remote reader 91 15 U300) can simultaneously recognize several LEGIC advant
user media (ISO 14443 A) within its detection field. Only the first user medium that corres-
ponds to the search criteria defined in the system is taken into account. All other user media
are ignored.
4.7
Functions
Depending on the configuration, the following functions are supported.
•
Authorisation check using badges and time-dependent authorisation
•
Control of the Registration unit (signal transmitter, optical and acoustic)
•
Control of the electric strike (doors with electric locking components)