dormakaba 9000 Delayed Egress Exit Device Installation
Instructions
95011817 (1135-88) IDE-20
01-2020
Exit Device
3
Specifications
Assembly
1.1 Specifications
91 00DE/9600DE
RI M
MO RT IS E
CVR
9300DE/9700DE
9500DE
Note: R efer to individual series i nstallation instructions for templating and installation of device; @ www.dormakaba.com
These are additional instructions for installation and operation of the "Delayed Egress" unit.
SIZE A: (9300DE/9500DE/9100DE)
Will fit 48" door opening without cutting.
Can be cut to fit a 40 1 /2" minimum door opening.
SIZE B: (9300DE/9500DE/9100DE)
Will fit 36" door opening without cutting.
Can be cut to fit a 34 1 /2" minimum door opening.
RE QUIRES dormakaba ES-1 00 or AD100 P OWER SU PPL Y.
Easily accessi ble slide in and out electronics.
Meets UL, ANSI/BHMA & CBC requirements.
SIZE AA: (9600DE/9700DE Series)
Will fit 48" (12 19 mm) door opening without cutting.
Can be cut to fit a 39 1/2" minimum door opening.
SIZE BB: (9600/9700DE)
Will fit 36" door opening without cutting.
Can be cut to fit a 32" minimum door opening.
85 Decibel Alarm - Standard
LED Status Indicator - Standard
Nuisance Alarm - Standard, DIP Switch Settable
Key Switch Control - Standard
Remote Authorized Egress - Standard, DIP Switch Settable
Remote Re-Arm - Standard
Remote Bypass - Standard
Door Position Input - Standard, DIP Switch Settable
Auto Reset or Manual Reset, DIP Switch Settable
Auto - Stanadard (Manual - in CA)
Additional Form "C" Relays For Optional Horn etc.
(Rated 1 amp @ 30 vdc)
Fire Alarm Connection
Paired Doors Connection
1.2 Assembly
Primary wire harness
End cap
End cap bracket
Filler (9000DE)
NOTE: "Always dis co nn ec t power prior to making
any co nn ec tion s or s ervice !"
Obse rve pr oper s tatic disc harge gr ou nding pr oc edures
when ins tallin g or s ervicing the Delayed Egr es s devi ce .
Touchbar/rail
assembly
(Delayed egress)
Connecting plugs
NOTE:
If cutting to length is required
carefully remove filler and
electronics for cutting. Use all
grounding precautions.
Mortise cylinder
(factory supplied)
Pt. No. 90J10SC118
Secondary wire harness
24Vdc input
313mA at alarm
Lock power provided by relay contacts rated at 24V, 8A.