Regular mount
2.2 Securing main arm to door/frame
Fig.3
Fig.4
2.2.1
Secure adjusting tube to damper.
•
Use one 7/8” x 1/2” torx head shoulder bolt provided.
2.2.2
Secure damper assembly to frame.
•
Use two 5/16” x 2” flat head screws
[#20 x 2” flat head wood screws] provided.
2.2.3
Secure main arm to operator pinion.
2.2.4
Use a torque wrench (25 ft-lbs) and provided pinion
screw [M8 x 30 socket head cap screw].
NOTE: To disassemble hold open plate:
2.2.5
Remove both screws from bottom of plate using a 3/16”
hex key.
2.2.6
Keeping all washers in place, flip plate over to orient as
per image above.
2.2.7
Re-secure plate with both screws.
2.3 Securing main arm to closer
2.3.1
Slide end of connecting arm into end of damper
assembly.
2.3.2
Secure connecting arm and damper assembly.
2.3.3
Use provided fastener [5/16-18 x 3/8 hex bolt].
Damper
Adjusting
tube
7/8"x1/2"
torx head
shoulder bolt
Pinion
Pinion
screw
Hold open
Main/
connecting
arm assembly
Right hand
door shown
Damper
Damper/
Damper
assembly
Pinion
Pinion
screw
Main/
connecting
arm assembly
Adjusting
tube
Right hand
door shown
Left Hand (LH)
Configuration
Plate pointing to the
LEFT
Right Hand (RH)
Configuration
Plate pointing to the
RIGHT
Hold open
plate
Non-hold open
Door
Hinge
Main arm
Damper
assembly
5/16-18 x 3/8"
hex bolt
Connecting
arm
Right hand
door shown
Right hand
door shown