MUNDUS PREMIUM PT 20
—
Montageanleitung – Oberer Eckbeschlag /
Mounting instructions – Top patch fitting
2
Safety-related Information
Important safety-related information for the mounting and use of dormakaba glass fittings.
(Follow these instructions in addition to the mounting and operating instructions in order to avoid damage of product and
damage to person or property.)
Important: All users have to be informed about relevant points mentioned in these safety-related information and the
mounting and operating instructions!
General information
1.
dormakaba recommends using of „heat soaked toughened safety glass“ (TSG-H)
DIN EN 12150-1
in accordance with
or the using of „l
.
aminated safety glass“ (LSG) in accordance with EN ISO 12543-1
2.
dormakaba glass fittings are not suitable for application in rooms where chemicals (e. g. chlorine) are used such as
indoor swimming pools, saunas or salt-water pools.
3.
Do not swing the doors with excessive force. Install a door stop to prevent door from opening too far.
Mounting
1.
Only properly qualified and specially trained staff is authorized to mount dormakaba glass fittings.
2.
Never use glass with conchoidal fractures and/or damaged edges.
3.
Due to crushing hazards – among others in the area of the secondary closing edge – and possible injury caused by
breakage of glass during mounting, corresponding protective clothing (especially gloves and protective goggles) is
required.
4.
Clean clamping area with fat solvent (standard commercial cleaning agent) before mounting the glass fitting
(e. g. acetone).
5.
Never use clamping shoes on structured glass surfaces (except on satined glass) or glass of heavily varying thickness
unless with a corresponding levelling layer.
6.
Never use clamping shoes on self-cleaning coatings.
7.
When adjusting glass elements, always stick to the required clearance for the respective fitting. Adjust the clearance so
that the glass does not touch hard components such as glass, metal or concrete.
8.
Make sure not to use excessive force when mounting the glass (avoid local stress resulting from very tight screws).
Maintenance
Check fittings at regular intervals for proper positioning and smooth running and check the door for correct adjustment.
Especially highly-frequented door systems require inspection by properly qualified staff (specialized companies or installation
firms). Immediately replace damaged glass elements (no glass flaking and/or conchoidal fractures)! Only use suitable
cleaning and care products to clean the surfaces.