L6L
2. Assembly
9
2.4 Opening and closing the
terminal
The unlocking mechanism is accessed through the hole on
the underside of the terminal. If there is a lock in this hole,
remove the lock first.
To open the casing you need a rod-shaped tool (such as a
screwdriver) which you insert through the unlocking hole.
Using strong pressure, increasing in force on the unlocking
piece on the inside, the casing will spring open. (see right)
Then pull the top casing section vertically towards the wall
as far as it will go to remove it from the lower casing sec-
tion. Then swivel the top casing section to the left.
To close the unit, follow the same steps in the reverse order.
When working on the open casing, it is advisable to lock
the front using the front locking catch. This tool can also be
used to open the terminal.
Please note the following points:
• Do not allow the flat-band cable between the top and
bottom casing sections to be trapped when closing.
• The unlocking piece must be positioned to fit the guide.
• The top casing section can only be positioned parallel to
the bottom section based on the design.
When the top casing section is positioned on the bottom
casing section, the unit can be closed using even pressure
on the right and left-hand sides of the top casing section.
This means that an audible ‘click’ can be heard when the
unit is closed correctly.