background image

08101631

7 of 7

05/09

INS NO.

PAGE

Rev.

1

(25)

1

(25)

SEE NOTE 7

(5)

3/4

(14)

(29)

1-1/8

C

9/16

"A"

L

(19)

(ADJUSTABLE)

3/16

SWITCH TRIPPER REQUIRED
WITH OPTIONAL LATCH BOLT
MONITOR FEATURES.

SEE NOTE 4

1/4 x 20 X 1FIL. HD. MACH. SCREWS

2 INCLUDED

1-1/2

(38)

8-1/4

(210)

3/8

(10)

3/4

(19)

(229)

9

7/16

(11)

(6)

1/4

11/16

(17)

1/2

(13)

5-5/8

(143)

4-1/2

(114)

(98)

3-7/8

1-21/32

(42)

(43)

1-45/64

(19)

3/4

(19)

3/4

110 ELECTRIC STRIKE (TEMPLATE)

NOTES:

1. NUMBER OF WIRES WILL VARY PER FEATURES OF STRIKE.

2. CUT OFF ALL EXCESS WIRE NOT REQD. FOR INSTALLATION.
3. WIRES TO BE RUN FROM SIDE & REAR OF STRIKE TO

    CONDUIT CONNECTION.
4. ALL WIRING CONNECTIONS TO BE MADE AT THIS END OF
    STRIKE. IF RECTIFIER (OPTIONAL) IS USED IT MAY BE
    INSTALLED AT EITHER END OF STRIKE.

5. FACEPLATE ALSO AVAILABLE IN THICKNESSES OF 1/2" & 9/16"

6. REFER TO CATALOG FOR AVAILABLE FINISHES, VOLTAGES,

    AND OPTIONAL FEATURES.

7. DIMENSION "A" (KEEPER POSITION) IS ADJUSTABLE FROM

    .687" TO .844". TO ADJUST, LOOSEN THE TWO 12-24 HEX HD
    STRIKE MOUNTING BOLTS, REPOSITION STRIKE, AND
    RETIGHTEN BOLTS.

RECTIFIER, AS REQUIRED
BY VOLTAGE AND/OR FEATURES

Summary of Contents for ES 110-4 Series

Page 1: ...for use in fire rated doors can only be operated by momentary contact switching energized only when the push button is held depressed and cannot be held in the unlocked position 2 FAIL SAFE When powe...

Page 2: ...heck for proper voltage being supplied to the strike Check all wiring Check the coil resistance of the solenoid and compare it to the chart located on the wiring diagram to ensure the correct solenoid...

Page 3: ...24 x 3 8 HEX WASHER HEAD CAP SCS 2 Remove the upper cover held on by two 2 4 40 x 3 16 PHMS Removal of the upper cover should be done slowly because the locking cam spring may snap out of place Also...

Page 4: ...PIN LOCATION IN FIELD RECEPTACLE Door shown closed and locked GREEN LIGHT CLOSED LOCKED RED LIGHT OPEN UNLOCKED G CONTROLS SHOWN FOR REFERENCE ONLY R Door shown closed and locked Dead Bolt extended in...

Page 5: ...IRING DIAGRAM R G Typical Control Schematic for Reference Only PUSH BUTTON TERMINAL STRIP AUXILIARY SWITCH LBM PURPLE ORANGE BROWN 9 3 6 1 4 Y R B BLACK RED YELLOW BLUE SOLENOID Lock Cam Bolt Monitor...

Page 6: ...TRIKE PREP LOCATION Measure distance from the mounting surface to tip of bolt This is DIM X DIM Y DIM X 3 32 2mm DIM Y is from edge of stop to centerline of prep Calculation assumes 3 32 2mm thick sil...

Page 7: ...ILL VARY PER FEATURES OF STRIKE 2 CUT OFF ALL EXCESS WIRE NOT REQD FOR INSTALLATION 3 WIRES TO BE RUN FROM SIDE REAR OF STRIKE TO CONDUIT CONNECTION 4 ALL WIRING CONNECTIONS TO BE MADE AT THIS END OF...

Reviews: