Troubleshooting

See also Commissioning

I

Adjustment

I

Functional

testing.

In the event of faults during start-up or operation,

first check the following

points;

Mains power available?

Emergency stop pushbutton unlatched?

Program switch in the correct position?
Light barrier transmission

paths clear and light barriers clean?

Door obstructed?

Door panels easy to move (counter-roliers,

floor guides)?

Fuse OK?

All external activators,

emergency stop switches, program switches and locks correctly wired?

All plugged connections

firmly

in place?

A\

For connection of the interconnecting

cable, completely open the corresponding terminal

by

unwinding the

ill

screw in a counter-clockwise

direction.

Insert the wire and tighten the screw.

For installation

work, remove plugs 11/12113 in order to disconnect

the control unit.

If the fault should not be remedied

by any of the above, use the hand terminal

(HO) for fault analysis. Further aids

are provided by the diagnostics

display on the expansion module and the information

for fault rectification

given in

the following

table.

---

Fault

Possible cause

Remedy

Door operates jerkily and in an

Plug connectors

Correctly fit the plug connectors

or

uncontrolled

manner.

Cable on incremental

encoder

swap over the wires.

~~

Incremental

encoder mode: on

Check the incremental

encoder

motorlreturn

pulley

mode with the HT.

0""'

on motor

1 ""' on the return pulley

After the "4-hourly

self-test",

the

Back-up battery not fully recharged,

Check back-up battery voltage.

door remains stationary

in

or now spent

Check operating

hours with HT.

OPEN - posltion.

Change back-up battery:

(only in the case of control units

with an expansion module)

Door remains open in all program

Light barriers (LS)

Check light barrier function

by

switch settings

observing the LEOs on EM 4 and HT

Emergency stop switch

Jumper the inputs at the connector.

If this rectifies

the fault, check the

emergency stop switch and replace
as necessary; test with HT.

Door does not open in the program

Activator internal/external

Remove connector

for activator,

and

switch settings "EXIT ONLY" and

jumper input. If this rectifies

the

'PARTIAL

OPENING".

fault, check the 24V power supply.

If also OK, check the activator and
replace as necessary.

Door will not open in program switch

Emergency stop switch

Jumper inputs at the connector.

If

setting 'AUTOMATIC"

and

this rectifies the fault, replace the

"PERMANENT

OPEN"

emergency stop switch

Door opens in program switch

Adjust or replace program switch.

setting "OFF"

Door stays open

Short~circuit"

Disconnect

control unit from mains

(Servicedisplay

is off)

power and conned

it again after

approx 3 seconds.

&,

*

Response of control units in the event of a short circuit.

The 24V power supply for radar detectors, electro. mechanical

locks and the motor connection

are of short-circuit-proof

design.

In the event of a short circuit,

the power supply unit interrupts

all secondary voltages and the operating

status

display is extinguished.

After rectification

of the short circuit,

the power supply unit does not automatically

switch on again! Remove pains plug, wait approx. 3 seconds and then re-insert mains plug.

Summary of Contents for ES 100

Page 1: ...n DORMA ES 90 100...

Page 2: ...UK training department1 2 25 20044 14 PM DORMA 6...

Page 3: ...UKT aining Dcpartll1e nt UK training departmentl 2 25 20044 14 PM t A f DORM 7...

Page 4: ...UK training department1 2 25 20044 14 PM DORMA 8...

Page 5: ...UK training department1 2 25 20044 14 PM DORMP 9...

Page 6: ...loses a short distance up to three times 8 Briefly depress the service pushbutton The door opens quickly the control unit stores the door parameters and then performs a back up battery test Ir When us...

Page 7: ...2 Turn the key switch counter clockwise Door should lock 5 Further information The door system performs a self test every 4 hours or at appropriate times after the system has been switched on In this...

Page 8: ...pliance with the standard and they can be adjusted using the hand terminal E5 901100 control units with molar type GR63x25 Opening speed 57 Creep speed CLOSE 53 DeeP speed distance ClOSE 100 Force lim...

Page 9: ...eans unlocking successfully completed 3x flashes means lockmg successfully completed lights up when both limit switches are either open or closed In the idle state Continuous Itght signals fault Buzze...

Page 10: ...v 8 controls The lock type must be programmed using the hand terminal If the enabled lock type is a concealed rod multipoint lock the Locking contact input on the EM 4 is converted to a disabling inpu...

Page 11: ...recharged Check back up battery voltage door remains stationary in or now spent Check operating hours with HT OPEN posltion Change back up battery only in the case of control units with an expansion...

Page 12: ...am switch in the sequence AUTOMATIC OFF AUTOMATIC Check the continuity from terminal 17 to terminal 20 Connect voltmeter to the terminals of the limit switch Initiate closing cycle During the closing...

Page 13: ...lay Condition Function e Normal mode Normal mode Mains power available power supply unit energised 0 Off unit not receiving mains power C Flashing frequency 2 Hz Learning cycle parameters are being de...

Reviews: