Troubleshooting
See also Commissioning
I
Adjustment
I
Functional
testing.
In the event of faults during start-up or operation,
first check the following
points;
Mains power available?
Emergency stop pushbutton unlatched?
Program switch in the correct position?
Light barrier transmission
paths clear and light barriers clean?
Door obstructed?
Door panels easy to move (counter-roliers,
floor guides)?
Fuse OK?
All external activators,
emergency stop switches, program switches and locks correctly wired?
All plugged connections
firmly
in place?
A\
For connection of the interconnecting
cable, completely open the corresponding terminal
by
unwinding the
ill
screw in a counter-clockwise
direction.
Insert the wire and tighten the screw.
For installation
work, remove plugs 11/12113 in order to disconnect
the control unit.
If the fault should not be remedied
by any of the above, use the hand terminal
(HO) for fault analysis. Further aids
are provided by the diagnostics
display on the expansion module and the information
for fault rectification
given in
the following
table.
---
Fault
Possible cause
Remedy
Door operates jerkily and in an
Plug connectors
Correctly fit the plug connectors
or
uncontrolled
manner.
Cable on incremental
encoder
swap over the wires.
~~
Incremental
encoder mode: on
Check the incremental
encoder
motorlreturn
pulley
mode with the HT.
0""'
on motor
1 ""' on the return pulley
After the "4-hourly
self-test",
the
Back-up battery not fully recharged,
Check back-up battery voltage.
door remains stationary
in
or now spent
Check operating
hours with HT.
OPEN - posltion.
Change back-up battery:
(only in the case of control units
with an expansion module)
Door remains open in all program
Light barriers (LS)
Check light barrier function
by
switch settings
observing the LEOs on EM 4 and HT
Emergency stop switch
Jumper the inputs at the connector.
If this rectifies
the fault, check the
emergency stop switch and replace
as necessary; test with HT.
Door does not open in the program
Activator internal/external
Remove connector
for activator,
and
switch settings "EXIT ONLY" and
jumper input. If this rectifies
the
'PARTIAL
OPENING".
fault, check the 24V power supply.
If also OK, check the activator and
replace as necessary.
Door will not open in program switch
Emergency stop switch
Jumper inputs at the connector.
If
setting 'AUTOMATIC"
and
this rectifies the fault, replace the
"PERMANENT
OPEN"
emergency stop switch
Door opens in program switch
Adjust or replace program switch.
setting "OFF"
Door stays open
Short~circuit"
Disconnect
control unit from mains
(Servicedisplay
is off)
power and conned
it again after
approx 3 seconds.
&,
*
Response of control units in the event of a short circuit.
•
The 24V power supply for radar detectors, electro. mechanical
locks and the motor connection
are of short-circuit-proof
design.
In the event of a short circuit,
the power supply unit interrupts
all secondary voltages and the operating
status
display is extinguished.
After rectification
of the short circuit,
the power supply unit does not automatically
switch on again! Remove pains plug, wait approx. 3 seconds and then re-insert mains plug.
Summary of Contents for ES 100
Page 1: ...n DORMA ES 90 100...
Page 2: ...UK training department1 2 25 20044 14 PM DORMA 6...
Page 3: ...UKT aining Dcpartll1e nt UK training departmentl 2 25 20044 14 PM t A f DORM 7...
Page 4: ...UK training department1 2 25 20044 14 PM DORMA 8...
Page 5: ...UK training department1 2 25 20044 14 PM DORMP 9...