Install track to frame.
Install with wire access plugs toward latch edge of door using (2) 1/4-20 x 2" metal or (2) No. 14 x 2-3/4" wood screws.
Route wires from frame through appropriate wire access hole in track, being careful not to pinch wires during installation.
QTY
(2)
QTY
(2)
(1)
QTY
ALARM CONTROL UNIT OR
SMOKE DETECTOR
U.L. LISTED
END CAP
COVER
8900PT ONLY
8
7
6
8900PT
8900T AND 8900DE
QTY
C HINGE
QTY
(1)
(1)
END CAP
END CAP
END CAP
Insert cover into track, align end cap in end of track.
Install remaining screw as shown using 1/4-20 x 2" metal or No. 14 x 2-3/4" wood screw.
QTY
(1)
Install PT track to soffit with wire access plugs toward hinge. Install with (1) 1/4-20 x 1-1/4" combo screw and (1) 1/4-20 x 2"
metal or (1) No.14 x 2-3/4" wood screw as shown. Route wires from frame through appropriate wire access hole in track,
being careful not to pinch wires during installation. ( DO NOT INSTALL END CAP ON HINGE SIDE IN THIS STEP)
(1)
QTY
Slide wiring connection cover to allow access to wire connections.
Determine power supply and unit voltage type: 24VAC, 24VDC. CAUTION!!! DO NOT CONNECT 120VAC TO A 24 VOLT UNIT TYPE!!!
Connect power supply wires to terminal block as shown (Terminal Block can be removed for easier wiring). Be sure to use
ground screw for power supply ground wire when supplying 120VAC. Slide wiring connection cover over wire connections.
Improper voltage to unit will result in damage to unit and void warranty.
state and local electrical codes.
All wiring must comply with national,
NOTE:
CAUTION:
WIRE CONNECTION COVER
SOLENOID WIRES
THIS CONNECTION IS NOT POLARITY DEPENDENT.
TERMINAL BLOCK
NOTE:
INCOMING POWER
CONNECTION
SMOKE DETECTOR
ALARM CONTROL UNIT OR
U.L. LISTED
TERMINAL BLOCK 18awg MAX.
INS NO.
PAGE
Rev.
08281000
2 of 5
08/13