1. Technical data
GB
Applications for single-leaf standard doors
Door leaf width
Door leaf weight, max.
Up to 330 lbs (depending on
door width; see diagram)
Door leaffi xing on the hinge (pull)
side (operator variant B)
With standard arm* (top jamb fixing
on the push side): 30 mm to 200 mm
Fixing positions
Top jamb fixing on the hinge (pull)
side
Door leaffi xing on the opposite
hinge (push) side (operator variant G)
Top jamb fixing on the opposite
hinge (push) side (operator variant G)
Frame reveal depth
With slide channel (all fixing
options) -30 mm to 30 mm
*
The standard arm is only provided for top jamb fixing on the
opposite hinge (push) side. Application of the standard arm increases
the forces of the door so that manual operation is still possible, but not
very comfortable. Where a standard arm is to be installed, DORMA
recommends use of an appropriate activator rather than the
Push&Go function.
Within the door opening angle of 0°-15°, static powers may exceed
150 N. Where the door is protected via force limitation, dynamic
powers according to DIN 18650 must be complied with and an
additional contactless protection must be installed if required.
Permissible door widths and weights
Technical data of the drive unit
Standard function programs and special functions
Prepared for connection of the following accessories
4
N
E
o
t
.
m
i
s
e
c
r
o
f
g
n
i
s
o
l
C
Dimensions
H
70 mm
L
660 mm
D
90 mm
Weight incl. mounting plate
8.5 kg
°
0
1
1
o
t
°
0
e
l
g
n
a
g
n
i
n
e
p
O
Class of protection
IP 20
TÜV type-approved
Compliant with Low Vol-
tage and EMC Directives
Manufactured to
ISO 9000:2000
Opening time adjustable
3 s to 6 s
Closing time adjustable
3 s to 10 s
similar to door closer
Hold open time adjustable
0 s to 30 s
Latching speed adjustable
Wall blanking adjustable
Opening angle adjustable
Angel for extended hold-open
function a
Delayed opening for locking
mechanism adjustable
Special
Push & Go
Power Assist ode
Extended
hold-open function
Door closer function under cut-out conditions
Sensortest (DIN 18650)
Anschluss testbarer Sensorik möglich
Softline slide channel
Standard arm
DORMA IRS-2-33/70/90/120 i
Activators (pushbutton, radar motion detector,
DORMA AutoSwitch…)
External program switch
Ratchet t pe hold open for Softline slide channel when
opening the door manuall under cut out conditions
Door closing force
according to prEN 12650/
DIN 18650 adjustable
Temperature range
0° to 40°
Relative humidity
up to 93%
Power supply data
230 V, 50/60 Hz
A
m
0
0
6
C
D
V
4
2
y
l
p
p
u
s
r
e
w
o
P
for external accessories
djustable
Functions via program switch
OFF
Automatic
Permanent Open
functions
included as standard
m
n
o
it
c
n
u
f
k
c
o
lr
i
A
l
a
n
o
it
p
O
special functions
Timed airlock
(additional accessories
function
n
o
it
n
u
f
-
p
o
lf
-
p
il
F
)
d
e
r
i
u
q
e
r
N ht- ank function
nfrared sensor
Door locking devices
Electric strikes (fail-safe/fail-secure principle)
DORMA SVP emergency escape motor lock with automatic
locking action
Access control system
Radio remote control
y
-
y
-
Adjustable parameters of the travel path
c
ig b
27” [700 mm] - 48” [1200 mm]
(depending on door weight;
see diagram)
optional
standard
600 700 800 900 1000 1100
1200 1300
Door width (mm)
)g
k(
th
gi
e
w
ro
o
D
0
160
140
100
120
80
60
20
40
Permissible
door specifications
1. Technical data
Applications for single-leaf standard doors
Door leaf width
27” [700 mm] - 48” [1200 mm]
(depending on door weight;
see diagram)
Door leaf weight, max.
Up to 330 lbs (depending on
door width; see diagram)
Fixing positions
Top jamb fixing on the hinge (pull)
side
Top jamb fixing on the opposite
hinge (push) side
Frame reveal depth
With slide channel (all fixing
options) -30 mm to 30 mm
*
The standard arm is only provided for top jamb fixing on the
opposite hinge (push) side. Application of the standard arm increases
the forces of the door so that manual operation is still possible, but not
very comfortable. Where a standard arm is to be installed, DORMA
recommends use of an appropriate activator rather than the
Push&Go function.
Within the door opening angle of 0°-15°, static powers may exceed
150 N. Where the door is protected via force limitation, dynamic
powers according to DIN 18650 must be complied with and an
additional contactless protection must be installed if required.
Permissible door widths and weights
Technical data of the drive unit
Closing force
Within BHMA/ANSI Standards
Door closing force
Within BHMA/ANSI Standards
Dimensions
H
2 3/4” [70 mm]
L
26” [660 mm]
D
3 1/2” [90 mm]
Weight incl. mounting plate 19 lbs [8.5 kg]
Opening angle
0° to 110°
Temperature range
0° to 40°
Relative humidity
up to 93%
Power supply data
115 V, 50/60 Hz
Power supply for external
24 V DC 600 mA
accessories
Class of protection
IP 20
UL 325 type-approved
Compliant with Low Voltage
and EMC Directives
Manufactured to
ISO 9000:2000
27”
31”
35” 40” 43” 48”
Door width (in)
Door weight (lb)
0
340
300
220
260
176
130
45
90
Permissible
door specifications
CD 80
Swing Door Operator
DORMA
6
DORMA AUTOMATICS, Inc.
924 Sherwood Drive
Toll-Free: 877-367-6211
DL2862-010
Lake Bluff, IL 60044
Fax: 877-423-7999
Jan. 2007
E-mail: [email protected]
Subject to change without notice
Adjustable parameters of the travel path
Opening time adjustable
3 s to 6 s
Closing time adjustable
3 s to 10 s
similar to door closer
Hold open time adjustable
0 s to 30 s
Latching speed adjustable
Wall blanking adjustable
Opening angle adjustable
Angle for extende hold-open
function adjustable
Delayed opening for locking
mechanism adjustable
Standard funtion programs and special functions
Functions cia programs switch OFF
Automatic
Permanent Open
Special functions
included as standard
Push & Go
Power Assist Mode
Extended
Hold-Open function
Optional
Airlock function
special funtions
Timed airlock function
(additional accessories
Flip-flop-function
required)
Night-bank function
Door closer funtion under cut-out conditions
Prepared for connection of the following accessories
Softline slide channel
Door locking devices
Electric strikes (fail-safe/fail-secure principle)
Access control system
Activators (puch button, radar motion detector,
DORMA AutoSwitch...)
Radio remote control
External program switch
standard
optional