background image

1.2 Electrical Rotary Joint Holders

The rotary joint is provided with 3 holders: the

Holder ERJ

,

Holder FRJ large

and the

Holder FRJ small

(Fig.

1.1

). To com-

bine electrical and optical signal, the

Holder ERJ

can be used in combination with the

Holder FRJ small

or the

Holder FRJ large

.

If the rotary joint is used only for electric signal, the

Holder FRJ large

alone (Fig.

1.1

). The gimbal mount

GH FRJ

(Fig.

1.1

)

can also be used with the rotary joint alone, while allowing moderate rotation along 2 axes.

Table 1.1:

Electrical Rotary Joint Holders

Holder ERJ

Holder FRJ small

Holder FRJ large

Gimbal Holder (GH FRJ)

Chapter 1. Overview

4

Summary of Contents for Electrical Rotary Joint

Page 1: ...Electrical Rotary Joint User Manual Version 1 1 1...

Page 2: ...lectrical Rotary Joint Holders 4 1 3 Rotary Joint Harwin 12 Omnetics PZN12 Adapter Kit 5 2 Operations Guide 6 2 1 Rotary Joint Holders 6 2 2 Electrical Optical Cables 9 3 Specifications 12 4 Support 1...

Page 3: ...it signal It is composed of a Stator which stays immo bile and a Rotor that moves Fig 1 1b The electrical signal is transmitted through 2 possible types of connectors Male Harwin 6 or 12 contacts or F...

Page 4: ...usedincombinationwiththeHolder FRJ smallortheHolder FRJ large If the rotary joint is used only for electric signal the Holder FRJ large alone Fig 1 1 The gimbal mount GH FRJ Fig 1 1 can also be used w...

Page 5: ...win 12 pin connector on one side and a Omnetics PZN12 connector on the other To use simply insert the Female Harwin connector in the Male Harwin connector on the Stator side of the rotary joint The pi...

Page 6: ...2 Operations Guide 2 1 Rotary Joint Holders 2 1 1 Holder ERJ a b c d Figure 2 1 Installation of the rotary joints in the Holder ERJ 6...

Page 7: ...er FRJ small is then be attached to the Holder ERJ frame 1 using 1 4 or M6 screws 2 and bolts 3 Fig 2 1d See Figure 2 2a for the final result For installation using the 1x2 Fiber optic Rotary Joint In...

Page 8: ...or M6 screws Figure 2 3 Installation of the ERJ in the Holder FRJ large 2 1 3 GH FRJ The Gimbal Holder allows swivel movement of the rotary joint along 2 axes The rotary joint is to be threaded into t...

Page 9: ...stalling the cables When not in use install plastic caps on connectors for protection and cleanliness 2 Connect the signal electrical cable to the fixed electrical connector Fig 2 5a and 2 5b 3 Connec...

Page 10: ...a subject patch cord connecting to the experimental subject 1 Connect the signal patch cord to the fixed connector of the optical rotary joint 2 Install the ERJ Holder as shown in section 2 1 1 3 Sele...

Page 11: ...Figure 2 7 Electrical and Fiber optic Rotary Joints Cable Installation Chapter 2 Operations Guide 11...

Page 12: ...ctrical Connector Configuration Male on rotary joint Female on adapter Table 3 2 HDMI Electrical Connector Configuration Male on cable Female on rotary joint Table 3 3 HDMI Electrical Connector Pinout...

Page 13: ...resistance 500 m Resistance variation during rotation 100 m 5 VDC During constant rotation Start up torque 0 9 mN m for 6 contacts Typical Value 1 9 mN m for 12 contacts Typical Value Rotation speed...

Page 14: ...urn instructions This warranty will not be applicable if the unit is damaged or needs to be repaired as a result of improper use or operation outside the conditions stated in this manual For more info...

Reviews: