NOTE:
The default configuration setting for alarm sound is set for 5 minutes
before rearming.
Set switches No. 2 and 3 for auto reset alarm time.
Three setting options: 1.5, 3 or 5 minutes.
If switch No. 1 is off, AL device re-arms with no delay.
6. To change the battery.
A. Remove end cap and loosen or remove mounting bracket.
B. Remove cover plate.
C. Change Battery.
D. Reassemble.
MODE SELECT SWITCHES
Auto reset time
Rearm time
Option
Function
Mode select
switches
End Cap
Bracket Screws
Cover Plate
On
AUTO RESET TIME
Switch No. 3
Switch No. 2
Factory settings shown
Minutes
On
WD-OD002(668)
DX-KA3-INST 2020-06
infinite
3
off
on
on
off
1-1/2
on
on
5
off
off
On
Auto reset time
Rearm time
Make sure polarity
is correct
-
End Cap
Screws
End Cap
End Cap
Bracket
9 Volt
Battery
+
-
+
1. Insert the key into the cylinder and turn clockwise to arm unit. Rotate to initial position to remove key.
2. Arming time is of 15 seconds, during which the LED flashes green every 1.5 seconds.
3. A brief sound will indicate that the alarming time is complete. When armed the LED will flash red every 15 seconds.
4. Turn the key counterclockwise to disarm.
5. Changing the battery:
A beep will sound every 15 seconds to indicate that battery is low. This cannot be shut down by disarming the unit
and the sound will stop only when battery is changed.
LED Indicator
Mortise Cylinder
{
OPERATION
OPTIONS