Route cable through hole and connect wires to power transfer
(see "POWER TRANSFER" instructions as needed).
NOTE: Alarm Exit Device does not contain dogging option.
IMPORTANT: Before installing battery, make sure
transmitting cam is in OFF position.
Check if polarity
is correct
Switch OFF
Position
-
-
5/16"
5/8" Diameter
Drill 5/8"dia. wire access hole thru device side of door.
L
C
Cylinder
Lock Nut
Thread cylinder lock nut onto mortise cylinder. Make
sure to fasten down tight.
9 Volt
Battery
Transmitting
Cam
1-1/4" Mortise
Cylinder
Power
Transfer
01. COMPLETE WIRING (IF REQUIRED)
02. INSTALL CYLINDER AND BATTERY
03. ATTACH WIRING TO TERMINAL BLOCKS ON ALARM EXIT MODULE
Power Supply
LM Switch
(Normally open contact)
NOTE:
1. The external inhibit (EI) option uses normally open (NO) dry access control
contacts to inhibit the AL.
2. Closing the access control contacts inhibits the AL. When the access control
contacts are re-opened, the AL re-arms with no delay.
3. All terminal inputs are not polarized.
(PS101/PS102 Class 2 Power Supply)
NO
COM
NC Violet
Gray
White
RX Switch
(Normally open contact)
EI
12VAC/24VAC
12VDC/24VDC
RX/LM
NO
NC Yellow
Contacts RX/LM
terminal block
OR
Blue
COM
Red
External Inhibit
(Normally open contact)
COM
NO
NC
2