Dorex DX KA Installation Instructions Download Page 2

+

+

Route cable through hole and connect wires to power transfer 

(see "POWER TRANSFER" instructions as needed).

NOTE: Alarm Exit Device does not contain dogging option.

IMPORTANT: Before installing battery, make sure 

                       transmitting cam is in OFF position.

Check if polarity 

is correct

Switch OFF 

Position

-

-

5/16"

5/8" Diameter

Drill 5/8"dia. wire access hole thru device side of door.

L

C

Cylinder 

Lock Nut

Thread cylinder lock nut onto mortise cylinder. Make 

sure to fasten down tight.

9 Volt 

Battery

Transmitting 

Cam

1-1/4" Mortise 

Cylinder

Power 

Transfer

01. COMPLETE WIRING (IF REQUIRED)

02. INSTALL CYLINDER AND BATTERY

03. ATTACH WIRING TO TERMINAL BLOCKS ON ALARM EXIT MODULE

Power Supply

LM Switch 

(Normally open contact)

NOTE:

 1. The external inhibit (EI) option uses  normally open (NO) dry access control          

                contacts to inhibit the AL.

            2. Closing the access control contacts inhibits the AL. When the access control 

                contacts are re-opened, the AL re-arms with no delay.

            3. All terminal inputs are not polarized.

(PS101/PS102 Class 2 Power Supply)

NO

COM

NC Violet

Gray

White

RX Switch 

(Normally open contact)

EI

12VAC/24VAC

12VDC/24VDC

RX/LM

NO

NC Yellow

Contacts RX/LM 

terminal block

OR

Blue

COM

Red

External Inhibit

(Normally open contact)

COM

NO

NC

2