Make  sure  to  fill  the  chilled  space  for  the  first  time  only  after  it  is  chilled  to  a  work 
temperature. Also follow this rule in the case of a longer shutdown. 
 

Periodically it is recommended to have a shutdown of the device to clean its interior, ensure a natural 

defrosting of the condenser and clean the condensing unit. 

Before  the  above  operations  are  carried  out,  make  sure  to  turn  off  the  device  with  power  switch  and 

unplug the power cord from the wall socket. 

To clean the condensing unit, remove ventilation grille from the encasing or the support structure.

 

 

Do not use water stream to clean the device 

Make sure to clean the condensing unit 

no less than once a month

. This should be carried out using a 

soft brush or a vacuum. 

 

The  manufacturer  cannot  be  held  responsible  for  damage  of  the  condenser  resulting  from 

failure to keep the condenser clean! 

All settings necessary for a normal operation of the device have been carried out by the manufacturer.

 

 
It  is  strictly  forbidden  to  tamper  with  system  parameters  of  the  controller  as  this  can  have 
very serious consequences, including damage of products and failure of chilling device.

 

 

The device is equipped with automatic condensate evaporation.

 

 

  TRANSPORT 

The manufacturer ships the device on a pallet, protected with card-board angles and foil. Make sure to 

protect the device against moving before transport. 

Transport the device in target working position. After reception of shipment (before unpacking) check if 

there  are  no  transport  damages.  If  any  damages  are  found,  report  them  to  the  carrier  immediately.  In  no 
case  should  the  damaged  device  be  returned  to  the  manufacturer  without  notice,  and  without  his  written 
consent. 

 

 

The manufacturer shall not be held responsible for the device damage during transport. 
 

 

Summary of Contents for DM-99006

Page 1: ...EN DORA METAL Sp ka z o o Edition 11 2017 INSTRUCTION MANUAL CHILLING EQUIPMENT COOLING MODULE DM 99006 ISO 9001 2000...

Page 2: ...manufacturer cannot be held responsible for use of the device for purposes other than intended not in accordance with the instructions or recommendations It is forbidden to cover shutter of condensin...

Page 3: ...INTENDED USE 4 OPERATION OF REFRIGERATION SYSTEM 4 SETTING CHAMBER TEMPERATURE 4 MOUNTING PRODUCT 5 PREPARATION FOR STARTUP CLEANING AND MAINTENANCE 5 CONNECTING TO WIRING SYSTEM 6 USAGE 6 TRANSPORT...

Page 4: ...temperature in the chamber To set a required temperature in the chamber Short press the button to display the set temperature By holding the button and using buttons set a desired parameter value the...

Page 5: ...should not be smaller than the area of outline of the condenser Make sure to position the unit at least 25cm from the wall PREPARATION FOR STARTUP CLEANING AND MAINTENANCE Commissioning and maintenan...

Page 6: ...have it replaced by a service technician or a qualified person holding adequate qualifications The devices are fitted with a terminal for connection of external equipotential bonds marked with Before...

Page 7: ...held responsible for damage of the condenser resulting from failure to keep the condenser clean All settings necessary for a normal operation of the device have been carried out by the manufacturer It...

Page 8: ...erant R134a GWP ODP 1430 0 Amount of factory filled refrigerant 0 3 kg CO2 equivalent 0 43 Added amount of refrigerant __ kg CO2 equivalent __ t Total amount of refrigerant in the circuit __ kg CO2 eq...

Page 9: ...NG DIAGRAM Czujnik komorowy Chamber sensor Czujnik parownikowy Evaporator sensor AGREGAT SKRAPLAJ CY CONDENSING UNIT OZNACZENIE KOLOR W PRZEWOD W WIRING COLOURS Barwa Colour niebieska blue br zowa bro...

Page 10: ...w dora metal pl e mail info dora metal pl serwis dora metal pl Service tel 602 286 179 Information herein is subject to change by DORA METAL without prior notice No part of this document can be reprod...

Reviews: