EN - DORA METAL Spółka z o.o. 

 

Chilling equipment

 

 

  INTENDED USE 

Cooling module manufactured by DORA METAL is within a group of professional chilling equipment. It 

is  designed  to  be  mounted  under  a  granite  plate  to  cool  its surface  which used  for a  short-term  display  of 
cold snacks, desserts, etc. and products in GN containers, and keeping them at cooling temperatures. 

Note: The cooling module is not intended for mounting in products designed for display of products on 

ice. 

It can be used in restaurants, salad bars, pizzerias, etc. where it is necessary to display chilled foods to 

retain their taste, aroma and appearance. 

  OPERATION OF REFRIGERATION SYSTEM.  

The  device  works  in  a  single  compression  refrigeration  cycle.  The  refrigeration  system  is  filled  with 

environmentally-friendly  refrigerant  approved  for  use  by  the  regulations  in  force  (see  data  plate).  The 
expanding element as a capillary tube is used. 

  SETTING CHAMBER TEMPERATURE 

Control  and  readout  of  work  parameters  is  possible  by  means  of  a  digital  controller  with  display.  The 

controller is programmed so the device reaches work temperature as given in technical data. 

LAE

 

CONTROLLER 

BASIC OPERATION 

Depending on version of the cooling device, the power can be switched on 
using key switch found on control panel of the device, or by pressing 

 

button on the controller. When the device is turned on, the display of the 
device will show air temperature in the chamber. 
To set a required temperature in the chamber: 

 

Short press the 

 button to display the set temperature. 

 

By holding the 

 button, and using 

 & 

 buttons, set a desired parameter value (the value must 

be within SPL & SPH values) 

 

Once the 

 button is released, a newly set value is saved. 

 

 

A

DDITIONAL INFORMATION

 

  Defrosting: 

During operation of the device, at regular time intervals “

DEF

” message is displayed, which means that the device 

operates in cooler defrosting mode. The defrosting cycle and its duration is defined by the manufacturer of the device 
and user cannot modify this parameter. If additional defrosting of cooler caused by difficult working conditions is needed, 

press and hold the

 button for 2 seconds. The display will show “

DEF

”. Defrosting will end automatically once time 

or temperature set by the manufacturer is reached.

 

 

Alarms:

 

Meaning of messages which can be appear on the display: 

E1   

 -  Damage of chamber temperature sensor.  

E2    - 

Damage of evaporator temperature sensor. 

DEF  - 

Enabled defrosting cycle (see 

Defrosting

CL  -

   

Warning on the need to clean the condenser

 

Attention! CL message 

Turning off 

CL

 reminder on the need to clean the condenser 

 

(every 4 weeks): 

- press the 

 button until 

CND

 message is displayed, 

- then, while holding the 

 button, press the 

 button. 

After this the CND parameter will be reset, and the cycle will start again. 
 

ATTENTION! Key lock 

A very common mistake made by users, is to cause an 

unintended key lock

, which makes menu of the controller 

inaccessible. Failure to check setting of the key lock option results in sending the controller to the dealer as “damaged”. 

Summary of Contents for DM-99006

Page 1: ...EN DORA METAL Sp ka z o o Edition 11 2017 INSTRUCTION MANUAL CHILLING EQUIPMENT COOLING MODULE DM 99006 ISO 9001 2000...

Page 2: ...manufacturer cannot be held responsible for use of the device for purposes other than intended not in accordance with the instructions or recommendations It is forbidden to cover shutter of condensin...

Page 3: ...INTENDED USE 4 OPERATION OF REFRIGERATION SYSTEM 4 SETTING CHAMBER TEMPERATURE 4 MOUNTING PRODUCT 5 PREPARATION FOR STARTUP CLEANING AND MAINTENANCE 5 CONNECTING TO WIRING SYSTEM 6 USAGE 6 TRANSPORT...

Page 4: ...temperature in the chamber To set a required temperature in the chamber Short press the button to display the set temperature By holding the button and using buttons set a desired parameter value the...

Page 5: ...should not be smaller than the area of outline of the condenser Make sure to position the unit at least 25cm from the wall PREPARATION FOR STARTUP CLEANING AND MAINTENANCE Commissioning and maintenan...

Page 6: ...have it replaced by a service technician or a qualified person holding adequate qualifications The devices are fitted with a terminal for connection of external equipotential bonds marked with Before...

Page 7: ...held responsible for damage of the condenser resulting from failure to keep the condenser clean All settings necessary for a normal operation of the device have been carried out by the manufacturer It...

Page 8: ...erant R134a GWP ODP 1430 0 Amount of factory filled refrigerant 0 3 kg CO2 equivalent 0 43 Added amount of refrigerant __ kg CO2 equivalent __ t Total amount of refrigerant in the circuit __ kg CO2 eq...

Page 9: ...NG DIAGRAM Czujnik komorowy Chamber sensor Czujnik parownikowy Evaporator sensor AGREGAT SKRAPLAJ CY CONDENSING UNIT OZNACZENIE KOLOR W PRZEWOD W WIRING COLOURS Barwa Colour niebieska blue br zowa bro...

Page 10: ...w dora metal pl e mail info dora metal pl serwis dora metal pl Service tel 602 286 179 Information herein is subject to change by DORA METAL without prior notice No part of this document can be reprod...

Reviews: